4 : Rotational (Ld, Lq, R, back-EMF)
5 : High Frequency Injection
T2-02: PM Motor Code Selection
No.
Name
(Hex.)
T2-02
PM Motor Code Selection
(0751)
Enter the motor code in T2-02 to automatically set parameters T2-03 to T2-14. When you are operating a specialized
motor or a non-Yaskawa motor designed, set T2-02 = FFFF and enter the data from the motor nameplate or the motor
test report.
You can only enter the permitted PM motor codes. Different drive control methods will accept different PM motor
codes.
T2-03: PM Motor Type
No.
Name
(Hex.)
T2-03
PM Motor Type
(0752)
0 : IPM motor
1 : SPM motor
T2-04: PM Motor Rated Power
No.
Name
(Hex.)
T2-04
PM Motor Rated Power
(0730)
T2-05: PM Motor Rated Voltage
No.
Name
(Hex.)
T2-05
PM Motor Rated Voltage
(0732)
T2-06: PM Motor Rated Current
No.
Name
(Hex.)
T2-06
PM Motor Rated Current
(0733)
T2-07: PM Motor Base Frequency
No.
Name
(Hex.)
T2-07
PM Motor Base Frequency
(0753)
YASKAWA SIEPC71061737B GA800 Drive Technical Reference
V/f
CL-V/f
OLV
CLV
AOLV
If the drive is operating a Yaskawa PM motor from the SMRA, SSR1, or SST4 series, enter the PM
motor code in accordance with the rotation speed and motor output.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of PM motor the drive will operate.
V/f
CL-V/f
OLV
CLV
AOLV
Uses the units set in o1-58 [Motor Power Unit Selection] to set the PM motor rated output power.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated voltage (V) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated current (A) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base frequency (Hz) of the motor.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.12 T: Auto-Tuning
Default
(Range)
FFFF
(0000 - FFFF)
Default
(Range)
1
(0, 1)
Default
(Range)
Determined by o2-04, C6-01
(0.00 - 650.00 HP)
Default
(Range)
200 V Class: 230.0 V, 400 V:
460.0 V
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
Default
(Range)
Determined by o2-04
(10% to 200% of the drive
rated current)
Default
(Range)
60.0 Hz
(0.0 - 590.0 Hz)
12