Configuration 2: Two-circuit (four power wires plus protective earth)
Power specifications, model M2K88A (Regulatory Model Number: VCVRA-1804)
Dedicated line
Number of power wires
Input voltage
Input frequency
Maximum power consumption, circuit 1 (L1N1)
Maximum power consumption, circuit 2 (L2N2)
Maximum load current, circuit 1 (L1N1)
Maximum load current, circuit 2 (L2N2)
Branch circuit breaker (required)
Copper wire, minimum cross-sectional area
Power wire terminals
Protective Earth (PE) terminal
The four power wires are circuit 1: L1N1 and circuit 2: L2N2.
1
This product has been evaluated to ±10% of the rated nominal voltage range (200–240 V) to allow for line fluctuation.
2
If the wire is more than 4.5 m (15 ft) long, HP recommends increasing the wire gauge appropriately.
3
WARNING!
incorporated in the equipment (5 kA rated interrupting capacity).
Power specifications, model M2K85B and M2K86B (Regulatory Model Number: VCVRA-1804-01)
Dedicated line
Number of power wires
Input voltage
Input frequency
Maximum power consumption, circuit 1 (L1N1)
Maximum power consumption, circuit 2 (L2N2)
Maximum load current, circuit 1 (L1N1)
Maximum load current, circuit 2 (L2N2)
Branch circuit breaker (required)
Copper wire, minimum cross-sectional area
Power wire terminals
20
Chapter 4 Plan the printer production area and environment
Ensure that mains fault current is compatible with proper operation of the protection devices
Yes
4 + Protective Earth (PE) wire
1
200–240 V
2
50/60 Hz
3150 W
3150 W
20 A (200–220 V)
16 A (221–240 V)
20 A (200–220 V)
16 A (221–240 V)
2 poles, 16 or 20 A (Europe)
2 poles, 30 A (rest of the world)
4 mm² (12 AWG) with a 16 or 20 A circuit breaker
6 mm² (10 AWG) with a 30 A circuit breaker
Straight wire to terminal block
Straight wire with ferrule to ground block
Yes
4 + Protective Earth (PE) wire
1
200–240 V
2
50/60 Hz
3600 W
3600 W
20 A
20 A
2 poles, 20 A (Europe)
2 poles, 30 A (rest of the world)
4 mm² (12 AWG) with a 20 A circuit breaker
6 mm² (10 AWG) with a 30 A circuit breaker
Straight wire to terminal block
3
3
3
3