Installation
Tools Required:
Two adjustable wrenches
1. Perform Pressure Relief Procedure, page 8.
2. Turn off and relieve air pressure in the air supply
hose.
3. Remove fluid spray hose from sprayer in
preparation for installation of zinc circulation kit.
4. Apply sealant to all non-swiveling pipe threads.
5. Using wrenches, install Zinc Circulation kit to the
pump outlet as shown in Parts, page 18. Fully
tighten each component with wrenches.
6. Flush and prime before using. See Flush, page 11,
and Prime, page 14.