Flush

To avoid fire and explosion, always ground
equipment and waste container. To avoid static
sparking and injury from splashing, always flush at
lower possible pressure.
Flush the Pump:
Before first use
When changing fluids
Before repairing equipment
Before fluid dries or settles out in a dormant pump
(check the pot life of catalyzed fluids)
At the end of the day
Before storing the pump
Flush at the lowest pressure possible. Flush with a fluid
that is compatible with the fluid you are pumping and
with the wetted parts in your system. Check with your
fluid manufacturer or supplier for recommended
flushing fluids and flushing frequency.
1. Perform Pressure Relief Procedure, page 8.
2. Remove tip and tip guard from gun.
3. If desired, remove fluid filter (sold separately).
Reinstall filter cap after removing fluid filter.
4. Connect the ground wire (L) and clamp to a true
earth ground.
5. Place suction tube in a compatible solvent.
NOTE: Do not stretch hose tight. Let it hang to assist
fluid flow into the pump.
3A9126A
6. Place return tube in a compatible solvent. Open
return line valve.
7. Turn air regulator adjustment knob (G)
counterclockwise until air pressure gauge (E) reads
zero.
8. Open bleed type master air valve (B).
9. Slowly turn air regulator adjustable knob (G)
clockwise until pump begins to cycle and a steady
stream of fluid emerges from return tube.
10. When clean solvent fluid flows out of return tube,
close return air valve. Pump will stall.
Flush
11