Pistol-grip mastic flo-gun for spraying heavy mastic sealants (12 pages)
Summary of Contents for Graco 222973
Page 1
WITH DURA-FLOt 1800 DISPLACEMENT PUMP 315 bar, 31.5 MPa (4500 psi) Maximum Working Pressure 7 bar, 0.7 MPa (100 psi) Maximum Air Inlet Pressure Part No. 222973, Series B With High Pressure Fluid Filter Part No. 238144, Series B With High Pressure...
Page 3
SKIN INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. D Fluid injected into the skin might look like just a cut, but it is a serious injury.
Page 4
FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Refer to Grounding on page 5. D If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately.
Page 5
General Information NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor. Refer to the Product Data Sheet for your pump, Form No. 305756.
Page 6
Supplied Components Refer to Fig. 2. WARNING A red-handled bleed-type master air valve (50) and a fluid drain valve (D) are supplied. These accesso- ries help reduce the risk of serious injury, including fluid injection and splashing of fluid in the eyes or on the skin, and injury from moving parts if you are adjusting or repairing the pump.
Page 7
SUPPLIED WITH ALL MODELS Pump Cart Pump Intake Bushing 12 Suction Hose 13 Suction Tube 14 Elbow 18 Fluid Filter (includes drain valve) 33 Pump Air Regulator 46 Air Manifold 50 Red-Handled Bleed-Type Master Air Valve (required, for pump) 57 Ground Wire (required; see page 5 for installation instructions) 67 Fluid Shutoff Valves 68 Air Line Male Coupler...
Pressure Relief Procedure WARNING SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:...
Page 9
CAUTION To avoid tip-over, the cart must be on a flat and level surface. Failure to follow this caution could result in injury or equipment damage. Prime the Pump 1. See Fig. 3. Remove the tip guard and spray tip from the gun (102).
Page 10
Shutdown and Care of the Pump WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. For overnight shutdown, stop the pump at the bottom of its stroke to prevent fluid from drying on the ex- posed displacement rod and damaging the throat packings.
Page 11
12 Suction Hose 13 Suction Tube 18 Fluid Filter 33 Pump Air Regulator 50 Red-Handled Bleed-Type Master Air Valve (required, for pump) 67 Fluid Shutoff Valve 68 Air Line Male Coupler 69 Air Line Female Coupler 102 Airless Spray Gun 103 Electrically Conductive Fluid Supply Hose Bleed-Type Master Air Valve (for accessories) Fluid Drain Valve (required)
Page 12
Part No. 222973, Series B (includes items 1–74) Part No. 238144, Series B (includes items 1–106) Ref. Part No. Description 237555 PUMP, Premier, 45:1 ratio; See manual 308147 for parts 236943 CART, portable Includes replacement items 2a–2d 112860 . WHEEL 107146 .
Page 13
Part No. 222973, Series B (includes items 1–74) Part No. 238144, Series B (includes items 1–106) * These parts are included in Suction Kit 222916, which may be purchased separately. 48 (Ref) Parts 2a 2c 2b 05914C 308215 05914B...
Category Maximum fluid working pressure Maximum air input pressure Ratio Pump performance data Air consumption data Air inlet size Fluid outlet size (at fluid filter) Fluid inlet size Maximum operating temperature * Sound level at 77 psi, 25 cycles/min * Sound power level at 77 psi, 25 cycles/min 103 dBa Wetted parts * Tested in accordance with ISO 3744.
Page 15
Pump Model 222973 1270 mm (50 in.) 238144 1270 mm (50 in.) Dimensions 864 mm (34 in.) 864 mm (34 in.) 737 mm (29 in.) 864 mm (34 in.) 864 mm (34 in.) 737 mm (29 in.) 05917 Width Across...
Graco Standard Warranty WARRANTY Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defec- tive.