Lenovo ThinkSystem SE350 V2 Manual page 170

Table of Contents

Advertisement

User Action:
Complete the following steps:
1. Power off the system.
2. Remove the unsupported Intel Optane PMEM from this system.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0047M: SPD CRC checking failed on DIMM [arg1]. [arg2]
Severity: Warning
User Action:
Complete the following steps:
1. Perform a virtual reseat or AC cycle the server.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0052I: DIMM [arg1] has been disabled due to the error on DIMM [arg2].[arg3]
Severity: Info
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Reseat the DIMM in the slot specified by the event message.
3. Restore A/C power and power on the system.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0053I: DIMM [arg1] re-enabled due to memory module combination updating.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0053M: DIMM [arg1] not defective but disabled due to unsupported memory module
combination on CPU [arg2].
Severity: Warning
User Action:
Complete the following steps:
1. This event could follow an uncorrectable memory error or failed memory test. Check the log and
resolve that event first. DIMMs disabled by other errors or actions could cause this event.
2. Ensure that the DIMM are populated in the correct sequence, according to the service information for
this product.
3. If DIMMs are present and properly installed, check for any lit DIMM connector error LEDs, and if
found, reseat those DIMMs, then check logs for memory diagnostic codes.
4. Reset UEFI to default settings.
5. If problem persists, update UEFI firmware.
6. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0065I: Multi-bit CE of DIMM [arg1] has been deasserted after performing post package
repair. DIMM identifier is [arg2].
Severity: Info
166