Table 3. Events organized by severity (continued)
Message String
Event ID
FQXSFSM0003N
Timed Out waiting on boot permission from Management Module:
System Halted.
FQXSFSM0004M
An XCC communication failure has occurred.
FQXSFSR0001M
[arg1] GPT corruption detected, DiskGUID: [arg2]
FQXSFSR0003G
The number of boot attempts has been exceeded. No bootable
device found.
FQXSFTR0001L
An invalid date and time have been detected.
FQXSFDD0004M
DRIVER HEALTH PROTOCOL: Reports 'System Shutdown' Required
Controller.
FQXSFDD0008K
Self-Encrypting Drive (SED) Error: failed to get key.
FQXSFDD0009K
Self-Encrypting Drive (SED) Error: failed to access drive [arg1].
FQXSFDD0010K
Self-Encrypting Drive (SED) Error: failed to unlock drive [arg1].
FQXSFDD0011K
Self-Encrypting Drive (SED) Error: failed to set password to drive
[arg1].
FQXSFDD0012K
SATA Hard Drive Error: [arg1].
FQXSFIO0005M
An intra-board UPI failure has been detected on the link between
processor [arg1] port [arg2] and processor [arg3] port [arg4].
FQXSFIO0006M
An inter-board UPI failure has been detected on the link between
processor [arg1] port [arg2] and processor [arg3] port [arg4].
FQXSFIO0007M
An error has been detected by the IIO on Bus [arg1]. The value of
Global Fatal Error Status register is [arg2]. The value of Global Non-
Fatal Error Status register is [arg3]. Please check error logs for
additional downstream device error data.
FQXSFIO0010M
An Uncorrectable PCIe Error has Occurred at Bus [arg1] Device [arg2]
Function [arg3]. The Vendor ID for the device is [arg4] and the Device
ID is [arg5]. The physical [arg6] number is [arg7].
FQXSFIO0011M
A PCIe parity error has occurred on Bus [arg1] Device [arg2] Function
[arg3]. The Vendor ID for the device is [arg4] and the Device ID is
[arg5]. The Physical slot number is [arg6].
FQXSFIO0012M
A PCIe system error has occurred on Bus [arg1] Device [arg2]
Function [arg3]. The Vendor ID for the device is [arg4] and the Device
ID is [arg5]. The Physical slot number is [arg6].
FQXSFIO0014J
A bad option ROM checksum was detected for the device found at
Bus [arg1] Device [arg2] Function [arg3]. The Vendor ID for the device
is [arg4] and the Device ID is [arg5]. The physical slot number is [arg6].
FQXSFIO0017M
IFM: Error communicating with the XCC - IFM may not be deployed
correctly.
FQXSFIO0019J
PCIe Resource Conflict [arg1].
FQXSFIO0024M
An error has been detected by the IEH on processor [arg1]. The type
of IEH is [arg2]. The index of the IEH is [arg3]. The value of
IehErrorStatus register is [arg4]. Please check error logs for additional
downstream device error data.
142
ThinkSystem SE350 V2 Messages and Codes Reference
Severity
Warning
Warning
Warning
Warning
Warning
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error