2. DC cycle the system.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFDD0010I: Self-Encrypting Drive (SED) Error: recovered from failure to unlock drive [arg1].
Severity: Info
User Action:
Information only; no action is required.
• FQXSFDD0010K: Self-Encrypting Drive (SED) Error: failed to unlock drive [arg1].
Severity: Error
User Action:
Complete the following steps:
1. Use recovery menu on XCC web to enter right encryption key to for the system.
2. DC cycle the system.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFDD0011I: Self-Encrypting Drive (SED) Error: recovered from failure to set password to drive
[arg1].
Severity: Info
User Action:
Information only; no action is required.
• FQXSFDD0011K: Self-Encrypting Drive (SED) Error: failed to set password to drive [arg1].
Severity: Error
User Action:
Complete the following steps:
1. DC cycle the system.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFDD0012I: SATA Hard Drive Error: [arg1] was recovered.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFDD0012K: SATA Hard Drive Error: [arg1].
Severity: Error
User Action:
Complete the following steps:
1. Power down the server.
2. Re-insert SATA Drive to ensure it is fully connected to the backplane.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFIO0005I: An intra-board UPI has been disabled on the link between processor [arg1] port
[arg2] and processor [arg3]port [arg4] because of UPI topology downgrade.
Severity: Info
.
147
Chapter 3
UEFI events