Lenovo ThinkSystem SE350 V2 Manual page 163

Table of Contents

Advertisement

User Action:
Complete the following steps:
1. Reseat affected DIMM.
2. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this
memory error.
3. Swap the DIMM to another known good location.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0013I: Mirror Fail-over complete. DIMM [arg1] has failed over to to the mirrored copy.
[arg2]
Severity: Info
User Action:
Check the system-event log for uncorrected DIMM failures and replace those DIMMs.
• FQXSFMA0014I: Memory spare copy initiated. [arg1]
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0015I: Memory spare copy has completed successfully. [arg1]
Severity: Info
User Action:
Check system log for related DIMM failures and replace those DIMMs.
• FQXSFMA0016M: Memory spare copy failed. [arg1]
Severity: Warning
User Action:
Complete the following steps:
1. Boot to uEFI F1 screen and make sure that all DIMMs are enabled. Reboot the system.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0023M: Error has occurred in NVDIMM flash. NVDIMM backup/restore may not operate
correctly. [arg1]
Severity: Error
User Action:
Complete the following steps:
1. Reseat the affected NDIMM, and the DIMM in the adjacent slots if populated.
2. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this
memory error.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0024M: Error has occurred in NVDIMM Supercap. NVDIMM backup/restore may not
operate correctly. [arg1]
Severity: Error
User Action:
.
159