Access Flow X stairli t - User Manual - Signals
6.3.3
SiGNALS WHEN OPERATiNG THE KEY LOCK
Signal
3 seconds of orange led + Warning
sound
3 seconds green led + warning sound
6.4

SiGNALS ON CALL-AND-PARK STATiON

Signal
Blinking green
light + start sound
(from stairli t
drive)
Blinking green
light for 5 seconds
+ arrival sound
(from stairli t
drive)
Blinking orange
light + warning
sound (from
stairli t drive)
Blinking orange
light 2 times
Blinking orange
light
Blinking red light
+ error sound
Blinking red light
+ warning sound
Meaning
The call-and-park button
has been operated and the
stairli t starts moving
The stairli t has arrived at
the halt point
Not all conditions are met:
the stairli t does not start.
Joystick or emergency
lowering button is active
The call-and-park battery
is low
Malfunction
Emergency stop button is
activated
Meaning
Key lock activation
Key lock de-activation
Action
Release the call-and-park
button
Check and meet all
conditions:
-
armrests locked in correct
position
-
safety belt fastened
-
key lock in status locked
Replace the batteries
Switch the stairli t o and
on again. If the stairli t does
not respond, contact your
supplier.
Deactivate the emergency
stop button