A-2

TECHNICAL SPECIFICATIONS:

CIRCULATOR
MAkE/MODEL
DESCRIPTION
CIRCULATOR
HEIGHT
213.6 in.
5425 mm
TEMPERATURE RANGE
41
0
F (5
0
C) to 113
FILTER MATERIAL
Cellulose fibers provided with precoat
COMPRESSED AIR QUALITY
Dry and Oil Free (ISO 8573-3 class 6)
COMPRESSED AIR CONNECTION
Quick Connect Coupling ø 9mm (CEJN 320)
INSULATION CLASS FAN
F with PTC

INSTALLATION

Model#: AD1326-8
AIR HANDLING
PHYSICAL DIMENSIONS
WIDTH
92.1 in.
2340 mm
0
F (45
0
C)
FILTER CLASS L
According to DIN EN 60335-2-69
OFFLINE CLEANING CYCLE DURATION
90 Minutes MAX
CIRCULATOR
INPUT
INPUT VOLTAGE
+/- 10%
380-480V/3~/50-60Hz
DEPTH
53.2 in.
1350 mm
RELATIVE HUMIDITY
FILTER SURFACE AREA
2 x 807 ft
REQUIRED PRESSURE
85 PSI (6 Bar) MAX
COMPRESSED AIR CONSUMPTION
Max: 5.3 ft
Depending on the degree of filter saturation
PROTECTION CLASS
NOMINAL CURRENT
(MAX.)
13.9A
WEIGHT
1764 lbs.
800 kg.
MAX. 80%
2
(2 x 75 m
2
)
/min. (87 lbs./in
)
3
2
IP54
A-2