A-7
Particulate Collection Drum
1. Mount the flexible duct connector onto the drum
flange and tighten the adjustable clamps using a
slot head screwdriver. See Figure A.11.
NOTE: Make sure the flexible duct covers and the
black rubber gasket are located on the drum
flange.
2. Remove shrink wrap and cardboard from the bot-
tom of the hopper.
3. Position the particulate collection drum directly
below the hopper.
4. Connect the other end of the flexible duct connec-
tor to the bottom of the hopper. See Figure A.11.
5. Fully extend the three turnbuckle distance holders
to meet the top of the collection drum. See Figure
A.11.
6. Make sure the damper is open. The damper con-
trol lever is located on the front of the particulate
collection drum and should be in the vertical posi-
tion when in operation.
FIGURE A.11
Compressed Air Connection
1. Connect compressed air line to pressure reducing
valve. Compressed air supply must be a minimum
of 90 PSI. See Figure A.12.
INSTALLATION
HOPPER
ADJUSTABLE CLAMPS
FLEXIBLE DUCT CONNECTOR
DRUM FLANGE
COLLECTION DRUM
CIRCULATOR
FIGURE A.12
PRESSURE
REDUCING
VALVE
Mounting the Control Panel
1. Install mounting hardware to back of control panel.
Note proper position of mounting bolts and nylon
washers. See Figure A.13.
2. Mount the control panel to the side of the fan cabi-
net.
3. If mounting to the top case rail, use ½" self tapping
screws
4. If mounting to the sheet metal, pre-drill holes and
use ½" mounting bolts with appropriate washers
and lock washers.
FIGURE A.13
A-7
NYLON WASHERS
MOUNTING BOLTS
S
CONTROL PANEL