AUTOMATIC SYSTEM START-UP

1. Follow Set Weekly Timer procedure.

OVERTIME SYSTEM START-UP

1. Press Overtime button.
a. Pressing button will override system to run
an additional 10 hours.
PLC START-UP PROCESS
1. Press q to show time and date.
2. Press ESC.
3. Select 'Start'..: Press q or
a. If "Stop" is the first item displayed, system
is already in START mode.
b. Press ESC.
4. Confirm "Start": Press OK.
5. Press ESC.

SET WEEkLY TIMER

There are four week timers (Timer 1 thru 4) installed
in the program, each consisting of three screens.
To change the timer settings, proceed as follows. This
procedure can be executed via the PLC display on the
outside of the control panel.
1. Press q to show time and date.
2. Press ESC.
3. Select 'Set Param': Press q or
4. Press OK.
FIGURE B.4
OPERATION
.
.
CIRCULATOR
5. Press t or u to change cursor position. Press q
or
to change value.
6. Press OK.
NOTE: Timer 1 - screen 4: make sure setting
Pulse = Off.
If desired, Timers 2 to 4 can be used to set
additional on/off moments of the fan, resulting
in a start up of the filter cleaning process.
7. Press
several times until Timer 2 shows up. Set
additional time settings.
8. Press ESC (3) three times to return to the date and
time screen.
Press Start.
Press STOP in case of emergency.
Troubleshooting Section in this manual.