Wiring Precautions The Part Which Matches The Emc Directives; Method To Connect The Power Wire And Ground Wire - Mitsubishi A950GOT User Manual

Table of Contents

Advertisement

8.3 Wiring Precautions the Part which Matches the
EMC Directives
Connect and wire GOT equipment as instructed below.
If the GOT equipment is configured in a way that differs from the following instructions
then the system will not comply with EMC directives.
8.3.1

Method to connect the power wire and ground wire

(1) With the power wire, be sure to attach the ferrite core (TDK type ZCAT3035-1330) within 90 mm of
the GOT terminal module.
Lead the power wire and ground wire as shown in Section 8.1.2 (2).
Always ground the FG wires.
<For A95*GOT>
Ferrite core
1 Wrap the power wire around the ferrite core.
*
8 - 9

8.3 Wiring Precautions the Part which Matches the EMC Directives

8.3.1 Method to connect the power wire and ground wire
GOT terminal block
*1
Get other manuals https://www.bkmanuals.com
<For A956WGOT>
GOT terminal block
0V
24V
INPUT
Ferrite core
*1