Table of Contents

Advertisement

Available languages

Available languages

Quick Links

View this manual online at www.lbwhite.com
Attention
The Oval tube heaters has been
designed, tested, and evaluated
by the L. B. White Company as a
radiant tube heater according to the
requirements of standard IAS U.S.
Requirements 8-94. All heaters
are designed specifically for the
intended use of heating poultry
confinement buildings.
CHECK WITH YOUR LOCAL
FIRE SAFETY AUTHORITY,
YOUR LOCAL FUEL GAS
SUPPLIER, OR THE L.B.
WHITE COMPANY IF YOU
HAVE QUESTIONS
REGARDING APPLICATIONS.
www.lbwhite.com
SEE ASSEMBLY
INSTRUCTIONS
INSIDE
Please refer to important
elevation information on
inside cover.
WORLD PROVIDER - INNOVATIVE CLIMATE SOLUTIONS
411 Mason Street, Onalaska, WI 54650 • 800-345-7200 • 608-783-5691 • 608-783-6115 (fax) • www.lbwhite.com
Owner's Manual and Instructions
Oval 80 v.2
Oval 90 v.2
Radiant Tube Heaters
Congratulations!
You have purchased the finest agricultural building heater available.
Your new L.B. White heater incorporates the benefits from the most experienced
manufacturer of heating products using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products and welcome
any suggestions or comments you may have...contact us at 1-(800)-345-7200,
or email us at customerservice@lbwhite.com.
The herein installation instructions are the L.B. White Co. LLC
suggested recommendations and guidelines for temporary or
permanent installation of the L.B. White Co. LLC heaters. Local,
state, and electrical and safety code requirements supersede these
guidelines. In the absence of local codes, see page 7 for
installation in the U.S. or Canada.
AR080
AR090
Propane Vapor Withdrawal
or Natural Gas
Listed under U.S. Patent #: 9,303,880
ACCESSORIES:
i.e. Regulator
not included and
is sold separately.
NOTICE
SCAN THIS
with your smartphone or
visit http://goo.gl/yyKxJo to
view maintenance videos
for L.B.White heaters.
* Requires an app like QR Droid
for Android or for iPhone
80,000 Btuh
90,000 Btuh

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for L.B. White Oval 90 v.2

  • Page 1 HAVE QUESTIONS manufacturer of heating products using state-of-the-art technology. REGARDING APPLICATIONS. We, at L.B. White, thank you for your confidence in our products and welcome any suggestions or comments you may have...contact us at 1-(800)-345-7200, or email us at customerservice@lbwhite.com.
  • Page 2: Table Of Contents

    Oval Radiant Tube Heaters TABLE OF CONTENTS Heater Specifications ......................4 General Information ......................5 Safe Clearance From Combustibles ................5 Temperature Sensor Location ..................5 Safety Precautions ......................6 Inlet Air Requirements ....................9 General Installation Instructions ...................10 Start-Up Instructions .....................16 Shut-Down Instructions ....................16 Cleaning Instructions ....................17 Maintenance Instructions ....................18 General Service Instructions ..................18 Troubleshooting Guide ....................25...
  • Page 3 ■ SAVE THIS OWNER’S MANUAL FOR FUTURE USE AND REFERENCE. ■ OWNER’S MANUALS AND REPLACEMENT LABELS ARE AVAILABLE AT NO CHARGE. SEE WEBSITE, OR FOR ASSISTANCE, CONTACT L.B. WHITE AT 1-800-345-7200. WARNING ■ PROPER GAS SUPPLY PRESSURE MUST BE PROVIDED TO THE INLET OF THE HEATER.
  • Page 4: Heater Specifications

    Oval Radiant Tube Heaters Specifications AR080 AR090 Available Tube Lengths (ft.) Maximum Input per Hour BTU/H 80,000 90,000 Fuel Consumption per LPG (lbs.) Hour (Max.) NG (ft. Gas supply pressure MAX. 13.5 acceptacle for the purpose of input adjustment (in.W.C.) MIN.
  • Page 5: General Information

    This manual will instruct you in the operation and care of your radiant heater. Have your qualified The L.B. White Co., Inc. has a policy of continuous installer review this manual with you so that you fully product improvement. It reserves the right to change understand the heater and how it functions.
  • Page 6: Safety Precautions

    Oval Radiant Tube Heaters Safety Precautions WARNING Asphyxiation Hazard ■ Do not use this radiant heater for heating human living quarters. ■ Do not use in unventilated areas. ■ The flow of combustion and ventilation air must not be obstructed. ■...
  • Page 7 Oval Radiant Tube Heaters Attention - Critical Points to Remember! 2. All installations and applications of L.B. White ■ Propane gas and natural gas have a distinctive odor. Learn to recognize these odors. (Reference heaters must meet all relevant local, state and “Fuel Gas Odor”...
  • Page 8 Oval Radiant Tube Heaters 9. The hose assembly shall be visually inspected on an annual basis. If it is evident there is excessive abrasion or wear, or if the hose is cut, it must be replaced prior to the heater being put into operation.
  • Page 9: Inlet Air Requirements

    Oval Radiant Tube Heaters Inlet Air Requirements -- All inlet air seams and joints must be sealed WARNING -- Do not use any filters on the air inlet system Combustion Hazard -- The air inlet system must be kept as ■...
  • Page 10: General Installation Instructions

    4 in. or 6 in. any building air inlet. General Installation Instructions 1. Read all safety precautions and follow L.B. White recommendations when installing this heater. If during 4. Ensure the heater installation does not the installation of the heater, you suspect that a part is interfere with water, gas, or electrical lines.
  • Page 11 ■ Failure to follow this warning can lead to fires proper functioning of the heaters. Consult your fuel or explosions. gas supplier, or the L.B. White Co., LLC for proper line ■ Fires or explosions can lead to property sizing and installation.
  • Page 12 BURNER DISCHARGE Oval Radiant Tube Heaters FIG. 6 18. Do not exceed input rating stamped on the FIG. 6 dataplate of the heater. Do not exceed the burner BURNER BOX BURNER BOX HANGING CHAINS HANGING CHA manifold pressure stated on the dataplate. Do not use an orifice size different than specified for the specific input rating of this heater, fuel type HANGING CHAIN DISTANCES...
  • Page 13 Oval Radiant Tube Heaters 5. The tube assembly should be either hung level, or with a downward slope away from the burner box not exceeding 1 in. for every 10 ft. of tube. FIG. 7 POSITION CLAMP EVENLY CLAMP BOLTS UP TUBE WELD SEAM DOWN ROUND TUBE HANGER INSTALLATION...
  • Page 14 Oval Radiant Tube Heaters Installing Reflectors & Supports Refer to Fig. 8 and the following instructions: 3. Connect the second reflector to the end of the first reflector with the dimpled connector strips. 1. Slide the reflector through the hangers until it is See Fig.
  • Page 15 Oval Radiant Tube Heaters Air Turbulation Strips FIG. 11 NIPPLE & Exhaust Vent Both strips are factory installed into the oval tube. At installation, ensure strips are snugly fit into oval tube and do not extend past end of tube. See Fig. 9. TO GAS CONTROL VALVE INLET FIG.
  • Page 16: Start-Up Instructions

    Oval Radiant Tube Heaters Heater Controls 2. Connect the electrical cord to an approved electrical outlet. WARNING 3. This heater includes a direct ignition control Electrical Shock Hazard module for purposes of controlling the timing of the ■ Disconnect the heater’s electrical supply before interconnecting the temperature control.
  • Page 17: Cleaning Instructions

    Oval Radiant Tube Heaters 2. With the heater lit, allow heater to burn off excess WARNING fuel in gas supply hose. 3. Turn thermostat to off or no heat position. This heater may be washed only on its external areas provided: 4.
  • Page 18: Maintenance Instructions

    Oval Radiant Tube Heaters Maintenance Instructions 3. Regulators can wear out and function improperly. Have your gas supplier check the date codes on all regulators installed and check delivery Before Each Use: pressures to the appliance to make sure that the regulator is suitable for continued use.
  • Page 19 Oval Radiant Tube Heaters Igniter 3. Pull the igntion cable’s rubber boot from the igniter. The tip of the igniter is exposed to a harsh environment B. MAINTENANCE consisting of high temperatures and combustion products. Periodic servicing is required. 1. Ensure the gap is 1/8 in. See Fig.17. A.
  • Page 20 Oval Radiant Tube Heaters Motor and Fan Assembly Air Differential Pressure Switch, Tubing and 1. Disconnect motor leads. Orifices. 2. Remove the four (4) motor mounting screws. See Fig. 18. Air inlet plate orifice: See Fig. 20. Ensure this orifice is free of dust. If the FIG.
  • Page 21 Oval Radiant Tube Heaters Air differential switch: The air differential switch orifices should be free of dirt. The air differential switch is a normally open, critical If cleaning is needed, use pressurized air. See picture safety device. See Fig. 22 for location. Its purpose is below.
  • Page 22 Oval Radiant Tube Heaters Gas Control Valve Transformer 1. Remove the hose from sediment trap. The transformer (Fig. 26) reduces the main power supply voltage to 24 VAC. The 24 VAC is sent to the 2. Remove the two nuts that secure the gas control valve’s ignition controller.
  • Page 23 Gas pressure gauges capable of FS: No terminal. reading up to 35 in. W.C. (may also be R: No terminal. ordered from L.B. White, part number X: No terminal. 00764) C/COM: Control and burner ground. Bushing, 1/2 in.x 1/8 in.
  • Page 24 Oval Radiant Tube Heaters 3. Open the burner box access panel. 3. If the inlet pressures do not agree with that specified on the dataplate, then the regulator controlling gas 4. Remove either the inlet or outlet pressure tap. pressure to the heater requires adjustment. See Fig.
  • Page 25: Troubleshooting Guide

    Oval Radiant Tube Heaters Troubleshooting Information A flashing light indicates a problem. The flash pattern will be followed by a pause and then a READ THIS ENTIRE SECTION BEFORE repeat of the flash pattern until the problem is corrected. BEGINNING TO TROUBLESHOOT PROBLEMS. Refer to the tables below to identify what page to refer to when troubleshooting any problems.
  • Page 26 Oval Radiant Tube Heaters Owner’s Manual • Oval Radiant Tube Heaters...
  • Page 27 Oval Radiant Tube Heaters Owner’s Manual • Oval Radiant Tube Heaters...
  • Page 28 Oval Radiant Tube Heaters Owner’s Manual • Oval Radiant Tube Heaters...
  • Page 29: Electrical Connection And Ladder Diagram

    Oval Radiant Tube Heaters Electrical Connection and Ladder Diagram Black/Negro Blue/Azul GV GV BK or/o W Brown/Marrón FAULT L.E.D.(RED) BR or/o R* LED DE CULPA (ROJO) Green/Verde GR or/o R* Orange/Naranja Red/Rojo White/Blanco Gas Control Valve/Válvula De L.E.D. Control De Gas Igniter/Encendedor IGC: Ignition Control/Control De...
  • Page 30: Parts Identification

    Oval Radiant Tube Heaters Service Parts Identification Schematic - Tube/Reflector Owner’s Manual • Oval Radiant Tube Heaters...
  • Page 31 Oval Radiant Tube Heaters Parts List - Tube/Reflector Item Description Part # Air turbulation strip (1 per kit) 572892 Exhaust Cap 573971 Tube, calorized, 3 in. x 10 ft., with clamp 572894 Tube, oval with clamp 572893 Clamp, 3 in. round, Oval 80 572842 Hanger, 3 in.
  • Page 32 Oval Radiant Tube Heaters Service Parts Identification Schematic - Burner Box Owner’s Manual • Oval Radiant Tube Heaters...
  • Page 33 Oval Radiant Tube Heaters Parts List - Burner Box Item Description Part # Latches and strike 573775 Red LED 573769 Green LED 573770 Wire harness 573681 Ignitor with bracket 500-24972 Ignition cable 572847 Air differential pressure switch 573682 Tube, air differential pressure switch 572883 Ignition Control 573946...
  • Page 34 Oval Radiant Tube Heaters Manual Rev./Changes Date Rev. Revision Change Description Released Owner’s Manual • Oval Radiant Tube Heaters...
  • Page 36: Warranty Policy

    Contact your local L.B. White dealer for replacement parts If neither is available, the warranty period will be 12 and service. You may also call the L.B. White Company, months from date of shipment from L B. White. LLC at 1-800-345-7200, for assistance, or email us at customerservice@lbwhite.com.
  • Page 37 INCENDIOS, SU PROVEEDOR En L.B. White, le agradecemos la confianza depositada en nuestros productos y serán bien DE GAS COMBUSTIBLE O L.B. recibidos los comentarios y las sugerencias que pueda tener. Llámenos a nuestra línea WHITE COMPANY.
  • Page 38 Calentadores de tubo radiante ovalado ÍNDICE Especificaciones del calefactor ..................4 Información general ......................5 Distancias de seguridad con materiales combustibles ...........5 Ubicación del sensor de temperatura ................5 Precauciones de seguridad ....................6 Requisitos de entrada de aire ..................9 Instrucciones generales de instalación .................10 Instrucciones de puesta en marcha ................16 Instrucciones de apagado ....................16 Instrucciones de limpieza .....................17...
  • Page 39 ■ GUARDE ESTE MANUAL DEL USUARIO PARA CONSULTARLO Y USARLO EN EL FUTURO. ■ LOS MANUALES DEL USUARIO Y LAS ETIQUETAS DE REPUESTO ESTÁN DISPONIBLES SIN COSTO. CONSULTE EL SITIO WEB O CONTÁCTESE CON L.B. WHITE AL 1-800-345-7200. ADVERTENCIA ■ SE DEBERÁ PROPORCIONAR UNA PRESIÓN DE SUMINISTRO DE GAS APROPIADA A LA ENTRADA DEL CALEFACTOR.
  • Page 40: Especificaciones Del Calefactor

    Calentadores de tubo radiante ovalado Especificaciones AR080 AR090 Longitudes de tubos disponibles (pies) Entrada máxima por hora en BTU/H 80 000 90 000 Consumo de combustible por LPG (libras) hora (máx.) NG (pie cúbico) Presión de suministro de gas MÁX. aceptable para el propósito de 13,5 ajuste de entrada (en...
  • Page 41: Información General

    Póngase en contacto con su distribuidor L. B. White o con L.B. White Company, LLC para obtener ayuda, o si Este manual le brindará instrucciones sobre el tiene preguntas sobre el uso del calefactor o sobre su funcionamiento y el cuidado de su calefactor radiante.
  • Page 42: Precauciones De Seguridad

    Calentadores de tubo radiante ovalado Precauciones de seguridad ADVERTENCIA Peligro de asfixia ■ No use este calefactor radiante para calefaccionar lugares donde vivan seres humanos. ■ No lo use en áreas sin ventilación. ■ El flujo de aire de ventilación y combustión no debe obstruirse. ■...
  • Page 43 2. Todas las instalaciones o aplicaciones de los cortada, debe reemplazarse antes de que se ponga calefactores de L.B. White deben cumplir con todos el calefactor a funcionar. El conjunto de la manguera los códigos locales, estatales y nacionales, incluidos debe protegerse de los animales y del contacto con los códigos de gas PL, de electricidad y de seguridad.
  • Page 44 Calentadores de tubo radiante ovalado repuesto de la manguera debe ser el que especifique el fabricante. Vea la lista de piezas. 10. Controle que no haya fugas de gas y que el funcionamiento sea adecuado tras la instalación del calefactor y antes de la repoblación del edificio. 11.
  • Page 45: Requisitos De Entrada De Aire

    Calentadores de tubo radiante ovalado Requisitos de entrada de aire -- Se deben sellar todas las costuras y uniones de ADVERTENCIA entrada de aire. Riesgo de combustión -- No utilice ningún tipo de filtro en el sistema de ■ Proporcione una entrada de aire fresco de tamaño y entrada de aire.
  • Page 46: Instrucciones Generales De Instalación

    1. Lea todas las precauciones de seguridad y siga las con las líneas de agua, de gas ni de electricidad. recomendaciones de L.B. White cuando instale este 5. Coloque la manguera de gas para evitar calefactor. Si durante la instalación del calefactor sospecha cualquier contacto con los tubos, los reflectores que una pieza está...
  • Page 47 ■ La inobservancia de advertencia puede provocar correcto de los calefactores. Comuníquese con su incendios o explosiones. proveedor de gas o con L.B. White Co., LLC para ■ Los incendios o las explosiones pueden causar determinar el tamaño adecuado de la línea y su daños materiales, heridas o la muerte.
  • Page 48 Calentadores de tubo radiante ovalado FIG. 6 17. Cualquier defecto que halle en la realización de alguno de los procedimientos de mantenimiento debe CAJA DEL QUEMADOR CADENAS DE eliminarse, y las partes defectuosas deben SUSPENSIÓN reemplazarse de inmediato. Vuelva a probar el calefactor antes de hacerlo funcionar otra vez.
  • Page 49 Calentadores de tubo radiante ovalado 3. Deslice los soportes de suspensión y conéctelos a las cadenas. 4. Conecte y cuelgue los tubos restantes. Siga los procedimientos detallados en el paso 2. 5. El conjunto de tubos se debe colgar a nivel o con una pendiente descendente con respecto a la caja del quemador, que no debe ser superior a 1 in cada 10 ft de tubo.
  • Page 50 Calentadores de tubo radiante ovalado Instalación de reflectores y soportes Consulte la Fig. 8 y las siguientes instrucciones: 3. Conecte el segundo reflector al extremo del primer reflector con las tiras conectoras con 1. Deslice el reflector a través de los soportes de hoyuelos.
  • Page 51 Calentadores de tubo radiante ovalado Tiras de turbulencia FIG. 11 NIPLE de aire y ventilación de escape Ambas tiras están instaladas de fábrica en el tubo ovalado. Durante la instalación, A LA ENTRADA DE LA VÁLVULA DE asegúrese de que las tiras estén bien CONTROL DE GAS NIPLE calzadas en el tubo ovalado y de que no...
  • Page 52: Instrucciones De Puesta En Marcha

    Calentadores de tubo radiante ovalado 2. Conecte el cable eléctrico a una toma eléctrica Controles del calefactor aprobada. ADVERTENCIA 3. Este calefactor incluye un módulo de control de encendido directo con el fin de controlar el ritmo del Peligro de descarga eléctrica proceso de encendido del calefactor además de ■...
  • Page 53: Instrucciones De Apagado

    Calentadores de tubo radiante ovalado Instrucciones de c. Cuando realice un lavado con agua, no rocíe agua en el interior de la caja del quemador o apagado de los tubos. Observe y respete la Advertencia de estas instrucciones de limpieza. La misma Advertencia se incluye en el calefactor.
  • Page 54: Instrucciones De Mantenimiento

    Calentadores de tubo radiante ovalado Instrucciones de 3. Los reguladores se pueden desgastar y pueden no funcionar adecuadamente. Pida a su proveedor de mantenimiento gas que verifique los códigos de fecha que figuran en todos los reguladores instalados y las presiones Antes de cada uso: que llegan al aparato para asegurarse de que el regulador sea adecuado para un uso continuo.
  • Page 55 Calentadores de tubo radiante ovalado Encendedor 3. Quite la funda de goma del cable del encendedor. La punta del encendedor está expuesta a un entorno hostil (correspondiente a las altas temperaturas y a los productos de la combustión). Se requiere un mantenimiento periódico B.
  • Page 56 Calentadores de tubo radiante ovalado Interruptor de presión Conjunto del motor y diferencial de aire, ventilador tubería y orificios de A. Extracción del conjunto de motor y turbina presión 1. Desconecte los dos (2) cables del motor. 2. Extraiga los tomillos de motaje del motor. Consulte la Orificio de la placa de entrada de aire: Fig.
  • Page 57 Calentadores de tubo radiante ovalado Interruptor de diferencial de aire: Los orificios del interruptor del diferencial de aire El interruptor del diferencial de aire es un dispositivo deben estar limpios. Si es necesario limpiarlos, use de seguridad crítico, comúnmente abierto. Consulte aire presurizado.
  • Page 58 Calentadores de tubo radiante ovalado Válvula de control de gas Transformador 1. Quite la manguera de la trampa de sedimentos. El transformador (Fig. 26) reduce el voltaje de la red de electricidad a 24 VCA. Los 24 VCA se envían 2.
  • Page 59 W: 24 V de CA desde el transformador hasta el para leer hasta 35 pulg. de columna de agua controlador. (Sin este voltaje, el control de encendido (también se puede pedir a L.B. White, número no funcionará). de pieza 00764) FS: Sin terminal.
  • Page 60 Calentadores de tubo radiante ovalado 4. Si la presión de entrada es correcta, pero la presión 3. Abra el panel de acceso a la caja del quemador. del colector del quemador no concuerda con la que 4. Quite el injerto a presión de entrada o salida. Ver Fig. 29. se especifica en la placa de datos, entonces se debe ajustar el regulador de presión interno de la válvula de FIG.
  • Page 61: Guía Para Resolver Problemas

    Calentadores de tubo radiante ovalado Información de resolución Una luz parpadeante indica que hay un problema. de problemas El patrón de destello será seguido de una pausa y luego la repetición del patrón de destellos, hasta que se corrija el LEA TODA ESTA SECCIÓN ANTES DE COMENZAR A problema.
  • Page 62 Calentadores de tubo radiante ovalado Manual del propietario • Calentadores de tubo radiante ovalado...
  • Page 63 Calentadores de tubo radiante ovalado Manual del propietario • Calentadores de tubo radiante ovalado...
  • Page 64 Calentadores de tubo radiante ovalado Manual del propietario • Calentadores de tubo radiante ovalado...
  • Page 65: Diagrama De Conexión Eléctrica Y Escalera

    Calentadores de tubo radiante ovalado Conexión eléctrica y diagrama de escalera Black/Negro Blue/Azul GV GV BK or/o W Brown/Marrón FAULT L.E.D.(RED) BR or/o R* LED DE CULPA (ROJO) Green/Verde GR or/o R* Orange/Naranja Red/Rojo White/Blanco Gas Control Valve/Válvula De L.E.D. Control De Gas Igniter/Encendedor IGC:...
  • Page 66: Identificación De Piezas De Servicio

    Calentadores de tubo radiante ovalado Diagrama de identificación de piezas de mantenimiento - Tubo / Reflector Manual del propietario • Calentadores de tubo radiante ovalado...
  • Page 67 Calentadores de tubo radiante ovalado Lista de piezas - Tubo / Reflector Ítem Descripción N.º de pieza Tira de turbulencia de aire (2 para Oval 80 y 3 para Sentinel) 572892 Ventilación de escape 573971 Tubo, de 3 pulg x 10 pies, con abrazadera 572894 Tubo, ovalado con abrazadera 572893...
  • Page 68 Calentadores de tubo radiante ovalado Diagrama de identificación de piezas de mantenimiento - Burner Box Manual del propietario • Calentadores de tubo radiante ovalado...
  • Page 69 Calentadores de tubo radiante ovalado Lista de piezas - Burner Box Ítem Descripción N.º de pieza Pestillos y pasador 573775 LED rojo 573769 LED verde 573770 Mazo de cables 573681 Encendedor con soporte 500-24972 Cable de encendido 572847 Interruptor de presión diferencial de aire 26809 Tubo, interruptor de presión diferencial de aire 572883...
  • Page 72 Política de garantía CALEFACTOR Algunos estados no permiten limitaciones respecto de la L.B. White Company, LLC garantiza que las piezas de su duración de una garantía implícita. Por lo tanto, la limitación de calefactor estarán libres de defectos en los materiales y arriba podría no aplicarse a usted.

This manual is also suitable for:

Oval 9 v.2Ar080Ar090

Table of Contents