Mitsubishi Electric VL-350CZPVU-L-E Installation Manual page 40

Lossnay heat recovery ventilator (residential use)
Hide thumbs Also See for VL-350CZPVU-L-E:
Table of Contents

Advertisement

6.4.5.3 Live switch
Set the operation for the live switch input (220-240 VAC input linked with a lighting switch etc.).
Live switch
Enable
Delay time
Overrun time
Fan
Select:
Cursor
F1
F2
6.4.5.4 Volt-Free contact
Set the operation for Volt-free contact input (input linked with non-voltage contact etc.).
Volt-free contact
Enable
Delay time
Overrun time
Fan
Select:
Cursor
F1
F2
No
/ Yes
20 min
20 min
Cursor
F3
F4
No
/ Yes
20 min
20 min
Cursor
F3
F4
Press the
and
button to move the cursor.
Press the
and
button to change the setting value.
Press the
button to save the changes.
[Enable]: Select [Use(Yes)/No use(No)] of the Live switch.
The factory default setting: No
[Delay time]: C hange the delay time for the start of the Live
switch operation from switch input ON.
The factory default setting: 20 min
Setting range: 0-120 mins (5-min intervals)
[Overrun time]: C hange the extension time from turning on
the switch input to the end of the live switch
operation.
The factory default setting: 20 min
Setting range: 0-120 mins (5-min intervals)
[Fan]: C hange the fan speed from the start to the end of the live
switch operation.
The factory default setting:
Press the
and
button to move the cursor.
Press the
and
button to change the setting value.
Press the
button to save the changes.
[Enable]: S elect [Use(Yes)/No use(No)] of the Volt-Free contact.
The factory default setting: No
[Delay time]: C hange the delay time for the start of the Volt-Free
contact operation from switch input ON.
The factory default setting: 20 min
Setting range: 0-120 mins (5-min intervals)
[Overrun time]: C hange the extension time from turning off the
switch input to the end of the Volt-Free contact
operation.
The factory default setting: 20 min
Setting range: 0-120 mins (5-min intervals)
[Fan]: C hange the fan speed from the start to the end of the
Volt-Free contact operation.
The factory default setting:
Eng-40