 GENERAL WORKING PRECAUTIONS
10. Handling connectors
• Do not install auxiliaries to the fuses. The fuses
may blow.
(1) Fuse
(2) Fusible link

10. Handling connectors

• When disconnecting the locking connectors, be
sure to disengage the lock before disconnecting.
There are two kinds of locks: one requires pressing
and the other requires pulling.
(A) Press
• Hold
on
tightly
to
disconnecting them.
• Do not pull wire harness itself.
03-CR-E4,03-CR-TE4BG
(3) Slow blow fuse
the
connectors
when
(B) Good
• Make sure the terminal condition of the connectors
is not bent, rusty, and so on.
• If the terminal is rusted, remove rust with
sandpaper.
However, do not polish the terminal of the
waterproof connector or the plated terminal.
(1) Missing terminal
(2) Bent terminal
(3) Sandpaper
• Cover the female bullet terminals and male bullet
terminals securely with the plastic covers.
• Make sure that the bullet terminals are secure and
connected securely to the tip.
(D) Good
(E) Bad: damaged cover
2. GENERAL
(C) Bad
(4) Rust
(F) Bad: poor connection
2-5
KiSC issued 02, 2021 A