Winco DP14000VE-03/A Installation And Operator's Manual

Winco DP14000VE-03/A Installation And Operator's Manual

Hide thumbs Also See for DP14000VE-03/A:

Advertisement

Quick Links

DP14000VE-03/A
GENERATOR
INSTALLATION AND
OPERATORS MANUAL
16200-007
www.wincogen.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DP14000VE-03/A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Winco DP14000VE-03/A

  • Page 1 DP14000VE-03/A GENERATOR INSTALLATION AND OPERATORS MANUAL 16200-007 www.wincogen.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SAFETY INFORMATION SAVE THESE INSTRUCTIONS SPECIFICATIONS GENERATOR ENGINE INTRODUCTION TESTING POLICY INTENDED USES RESTRICTED USES UNIT CAPABILITIES GENERATOR CONNECTIONS STARTING ELECTRIC MOTORS PREPARING THE UNIT UNPACKING LUBRICATION OIL RECOMMENDATIONS OIL ALERT SYSTEM FUELING BATTERY INSTALLATION BATTERY CHARGING LIFTING EYE INSTALLATION OPTIONAL DOLLY KIT INITIAL START UP...
  • Page 3: Safety Information

    SAFETY INFORMATION IMPORTANT SAFETY INSTRUCTIONS WARNING: FIRE HAZARD This engine generator set has been designed and Gasoline and other fuels present a hazard of possible manufactured to allow safe, reliable performance. Poor explosion and/or fire. maintenance, improper or careless use can result in A.
  • Page 4: Save These Instructions

    COPY YOUR MODEL AND SERIAL NUMBER HERE No other WINCO generator has the same serial number as yours. If you should ever need to contact us concerning this unit, it will help us to respond to your needs faster.
  • Page 5: Specifications

    SPECIFICATIONS GENERATOR Model DP14000VE-03/A Surge Watts 14,000 Continuous Watts 11,760 Volts 120/240 Amps 58/49 Generator Manufacturer Mecc Alte Generator Model Number S20F-230/A Part Number 16428-002 Capacitors 300323-112 (qty 1) 300323-212 (qty 2) ENGINE Engine Manufacturer Briggs & Stratton Engine Model Number...
  • Page 6: Introduction

    INTRODUCTION TESTING POLICY Before any generator is shipped from the factory, it is fully checked for performance. The generator is loaded to its full capacity, and the voltage, current, and frequency are carefully checked. Rated output of generator is based on engineering tests of typical units, and is subject to, and limited by, the temperature, altitude, fuel, and other conditions specified by the manufacturer of applicable engines.
  • Page 7: Unit Capabilities

    UNIT CAPABILITIES The heavy surge of current required for starting motors GENERATOR CONNECTIONS is required for only an instant. The generator will not be damaged if it can bring the motor up to speed in a few DP14000VE: 120 Volt and 240 Volt receptacles are seconds of time.
  • Page 8: Preparing The Unit

    If any damage is noted, it is always easiest to consumption. Check the oil level frequently. refuse the shipment and let WINCO take care of the freight 5W-30 claim. If you sign for the unit, the transfer of the ownership...
  • Page 9: Battery Installation

    Never use gasoline that has been stored for an extended normal operating conditions, but were not intended to be period of time as the fuel will lose its volatile properties used as a battery charger. and you will be left with varnish residue. The varnish like substance will clog the carburetor and will not burn WARNING properly.
  • Page 10: Initial Start Up

    INITIAL START UP STARTING HINTS WARNING: PERSONAL INJURY Improper maintenance, or failure to fix any problems 1. COLD WEATHER during operation, could cause equipment damage A. Use the proper oil for the temperature expected. and possible serious injury. Always inspect unit prior to B.
  • Page 11: Connecting The Loads

    CONNECTING THE LOADS A. Add the fuel stabilizer to the fuel in the tank and run for 2 minutes to circulate the stabilizer throughout the fuel system. The engine-generator covered in this manual was designed B. Remove the remaining fuel from the fuel tank, it must for portable use.
  • Page 12: Grounding

    GFCI protected generators. STANDARD PORTABLE GENERATOR 2. If the generator set is connected to an existing Your WINCO portable generator ships with a bonded distribution system, a fully isolated manual transfer switch neutral. You can safely use this generator without external must be installed.
  • Page 13: Yourgen

    YOURGEN overriding the governor and operating the generator at The WINCO YourGen meter allows you to see useful low voltage may damage both the generator and any load information about your generator from the front panel connected to it. Running the engine at excessively high...
  • Page 14 output) generator. A & B represent the 120 volt output legs of this generator. Up to 5,880 watts at 120 volts (58 Amps) can be drawn from the receptacles attached to either A or B output legs. This generator is capable of producing 58 Amps of 240 volt current at C.
  • Page 15: Engine Care

    Outdoor temperatures determine the proper oil viscosity for air filter on a hard surface. the engines. Winco recommends our 5W-30 fully synthetic If the air filter is excessively dirty oil to give you excellent protection in cold temperatures replace with a new filter. You...
  • Page 16: Spark Plug

    Then allow it to thoroughly air dry. DO NOT oil the pre- cleaner. 7. Install the pre-cleaner to the air filter 8. Assemble the dry pre-cleaner to the air filter 9. Install the air filter 10. Install the cover and secure with the fasteners SPARK PLUG CAUTION: EQUIPMENT DAMAGE Incorrect spark plugs can damage the engine.
  • Page 17: Generator Care

    GENERATOR CARE Proper care and maintenance of the generator is necessary to ensure a long trouble free life. EXERCISING THE GENERATOR The generator should be operated every three to four weeks. It should be operated for a period of time sufficient to warm the unit up and to dry out any moisture that has accumulated in the windings.
  • Page 18: Troubleshooting

    TROUBLESHOOTING Problem Possible Causes Won’t start Low oil level Fouled spark plug Out of fuel Start switch in OFF position Fuel Valve turned off Plugged fuel filter Blown fuse in key switch Weak or dead battery Voltage too low Engine speed is too low Generator overloaded Defective stator Defective rotor (field)
  • Page 19: Receptacle Wiring Diagram

    RECEPTACLE WIRING DIAGRAM OPM-167/A...
  • Page 20: Limited Warranty

    Air cooled units purchased for stock have 1 year to be sold. The warranty to the original retail customer commences on the date of sale of the product to them. All liquid cooled units have 180 days from the Winco invoice to submit a start up date.
  • Page 21 Standby use is defined as an application where utility power is present -and- the generator set is used as emergency backup during utility power outages. WINCO reserves the right to change or improve it’s products without incurring any obligations to make such changes or improvements on products purchased previously.
  • Page 22 22. Travel time or service calls unless specifically authorized by Winco, Inc. in writing. GENERAL INFORMATION The WINCO, Inc. Service Department is open from 7:30 AM to 4:30 PM Central Standard time. It is located at 225 South Cordova Ave., Le Center, MN, 56057-1805. Phone Numbers: Service Department - 507-357-6831 FAX Line - 507-357-4857.
  • Page 23: Ca Evap Emission Control

    2020 generator. In California, new equipment that uses small off-road engines must be designed, built, and equipped to meet the State’s stringent anti-smog standards. WINCO must warrant the evaporative emission control system on your generator for the period listed below provided there has been no abuse, neglect or improper maintenance of your equipment leading to the failure of the evaporative emission control system.
  • Page 24 225 S. CORDOVA AVE • LE CENTER, MN 56057 Sales: 507-357-6821• sales@wincogen.com Service: 507-357-6831 • service@wincogen.com www.wincogen.com OPM-167/A...

Table of Contents