Effects Of Programming On Custom Function Activation - Bosch D9412GV3 Program Entry Manual

Table of Contents

Advertisement

D9412GV3/D7412GV3 | Program Entry Guide | 6.0
All SDI devices, regardless of area
assigned, report to Area 1, Account 1 by
default upon SDI failure. If a D9210B
becomes disconnected, an SDI Fail ##
and a Missing Point ### Event is
created.
If the D9210B is not programmed with a
D# Entry Area, 9210 NOT READY
appears at the keypad with this door
assigned to it when you press the
[ENTER] key.
D#CC#Scope
Default:
0
Selection:
0 to 8
1 to 8
Determines disarming rights. The
user's access level and the CC #
Scope determines which areas are
disarmed.
0
Only the area assigned to the D#
Entry Area disarms this door.
Enter the keypad number (CC#) which determines
the scope of the user ID's disarming rights. Areas
disarm on the basis of this keypad's scope and the
authority level of the user.
The D# CC# Scope prompt is limited to
the first 8 keypads.
D# Custom Function
Default:
0 (Disabled)
Selection:
0, 128-143 (128-131 on the
D7412GV3)
0
Custom function disabled.
128-143
The custom function number that
executes upon a valid ID, given the
appropriate user access level and
area arm state.
You can program a custom function to run at the
keypad programmed for CC# Scope. This custom
function activates only for users with an L##
Function Level? Assignment (refer to Section 2.10
User Interface on page 76) in which a valid ID can
execute a custom function during the armed or
disarmed state. The user number to which the token
is assigned must have an assigned passcode.
Bosch Security Systems, Inc. | 10/11 | F01U170807-02
ACCESS CONTROL
If D# Disarm On Open is set to Yes for the same
door, and L## Function Level? is set to D or C, the
custom function executes when the door is physically
opened.
Table 39 on page 141 shows how this programming
affects custom function activation.
Table 39: Effects of Programming on Custom
L## Function
Level?
M
(Armed)
D
(Disarmed)
C
(Armed and
Disarmed)
-
D# Door Point
Default:
Selection:
1 to 127,
129 to 247
0
Enter the point number assigned to this door. This
point cannot be used for any other point
assignments.
Get other manuals https://www.bkmanuals.com
A user's access level and the armed state
of the area determine whether the custom
function activates. This access level is
programmed in the L## Function Level?
prompt. Refer to 2.10 User Interface on
page 59.
Function Activation
Custom Function Activation
User token activates the custom
function assigned to the Door
Controller only while the entry area
for the Door Controller is Master
Armed or Perimeter Armed.
User token activates the custom
function assigned to the Door
Controller only while the entry area
for the Door Controller is disarmed.
User token activates the custom
function assigned to the Door
Controller regardless of the armed
state of the entry area.
User token does not run the custom
function assigned to the Door
Controller.
A user's security level must have an M,
P, or D to operate the custom function.
0
0 to 127, 129 to 247(0 to 75 on the
D7412GV3)
The point number assigned to this
door. Points 128 and 248 are
reserved by the control panel for
internal use.
No point number is assigned to this
door.