Bosch D9412GV3 Program Entry Manual page 72

Table of Contents

Advertisement

D9412GV3/D7412GV3 | Program Entry Guide | 2.0
L## Add User
Default:
Refer to the program record sheet
Selection:
- or E
Function
Function Name
No.
18
Add User
Add or change users, add or change authority levels,
add or change tokens or cards.
9210 NOT READY appears if a door
controller is not assigned to the keypad
used to add or change tokens or cards.
Refer to CC# Assign Door in Section
2.9.1 Keypad (Command Center)
Assignment on page 53.
L## Del User
Default:
Refer to the program record sheet
Selection:
- or E
Function
Function Name
No.
19
Delete User
Delete users.
Although an individual user (001 through
249) can be deleted separately, use
caution with this function. User
passcodes, tokens or cards cannot be
deleted individually within a group. (For
example, User 001 has three additional
sub-users that use the same authority
levels for that group.) When dealing with
an individual user, change that user's
token or passcode so that other users in
the group do not need to be added again.
L## Extend Close
Default:
Refer to the program record sheet
Selection:
- or E
Function
Function Name
No.
20
Extend Close
Change the closing time in the area where the
function is entered.
Bosch Security Systems, Inc. | 10/11 | F01U170807-02
Panel and Area Wide Parameters
L## View Log
Default:
Selection:
Alternate
Function
Keystroke
No.
[COMMAND][5][6]
21
View all panel-wide events in the control panel's
memory log.
L## Print Log
Default:
Selection:
Function
No.
22
Print all panel-wide events from the log to the printer
in the area where the user is executing this function.
Alternate
Keystroke
[COMMAND][5][3]
L## User Cmd 7
Default:
Selection:
Function
No.
23
This command can be used in Function Menu.
Generate the alarm programmed at COMMAND 7 in
the POINTS > Command 7 / Command 9 section..
L## User Cmd 9
Default:
Selection:
Alternate
Keystroke
Function
No.
[COMMAND][5][1]
24
This command can be used in Function Menu.
Generate the alarm programmed at COMMAND 9 in
the POINTS > Command 7 / Command 9 section.
Get other manuals https://www.bkmanuals.com
Refer to the program record sheet
- or E
Function Name
Alternate
Keystroke
View Log
(Menu function
only)
Refer to the program record sheet
- or E
Function Name
Alternate
Keystroke
Print Event Log
(Menu function
only)
This item can also be accessed using the
Service Menu ([9][9][ENT]).
Refer to the program record sheet
- or E
Function Name
Alternate
Keystroke
User Command 7
[COMMAND][7]
Refer to the program record sheet
- or E
Function Name
Alternate
Keystroke
User Command 9
[COMMAND][9]