Zone Function Programming (Address 0001 To 0030, Data Digit 1); Zone Function Programming (Address 0001 To 0030, Data Digit 2); Address 0001 To 0030, Data Digit 1, If Data Digit 2 = 9 - Bosch DS7400XiV4-EXP Reference Manual

Wireless reference guide
Hide thumbs Also See for DS7400XiV4-EXP:
Table of Contents

Advertisement

DS7400XiV4-EXP | Wireless Reference Guide | 3.0
Table 4: Zone Function Programming (Address 0001 to 0030, Data Digit 1)
Select Options
Invisible Alarm
Silent Alarm
Steady Alarm Output
Pulsing Alarm Output
Alarm on Short
Alarm on Open
1
Trouble on Open
Trouble on Short
1
Only when disarmed. When armed, this becomes Alarm on Open or Short for non-24-hour zones.
NOTE: Multiplex contacts should not be programmed for Trouble on Open.
Table 5: Zone Function Programming (Address 0001 to 0030, Data Digit 2)
Select Options
Interior Delayed
Perimeter Instant
24-Hour
Entry/Exit Delay #1
Entry/Exit Delay #2
Interior Entry/Exit Follower
Interior Home/Away
Interior Instant
2
If Data Digit 2 = 9 (keyswitch), refer to Table 6 to determine the value for Data Digit 1.
Bosch Security Systems | 6/05 | 4998154962B
Value
0
1
2
3
4
5
6
7
Table 6: Address 0001 to 0030, Data Digit 1, if
Data Digit 2 = 9
Select Options
Single Partition – No Force Arm
Single Partition – Can Force Arm
All Partitions – No Force Arm
All Partitions – Can Force Arm
Adding Wireless Sensors/Contacts
Selections for Data Digit 1
0
1
2
3
4
5
6
Select Options
Day Monitor
2
Keyswitch
Fire Zone with Verification
Fire Zone without Verification
Waterflow
Supervisory
Entry/Exit Delay Cancel 1
Entry/Exit Delay Cancel 2
Value
0
1
2
3
7
8
9 *0 *1 *2 *3 *4 *5
Value
8
9
*0
*1
*2
*3
*4
*5
EN | 8

Advertisement

Table of Contents
loading