3. Installation Checklist

1. Voltage and proper grounding.
2. Valve properly secured (latched) to block.
3. CO
pressure to carbonator.
2
4. Water flow rate.
5. Syrup delivery pressure.
6. Finished product temperature less than 40°F.
7. Water to syrup ratio.
8. Portion size / top-off.
9. Water, syrup, CO
10. Cover secured to valve.
11. Valves flavor correctly marked.

4. Retrofitting

UF-1 and UFB-1 valves will retrofit any valve with an identical mounting block screw pattern.
Note: Replacement of mounting block inlet fitting O-rings (part # 4073) is required when retrofitting valves.

4.1 Mounting Block Removal

To remove valve mounting block from the front panel, take out and save 4 screws.
IMPORTANT: Before installing block replace O-rings on each outlet fitting. Lubricate with Dow 111 or
equivalent silicone lubricant. Do not use petroleum jelly.
© 2023, Marmon Foodservice Technologies Inc.
leaks.
2
- 16 -
Publication Number: 315222001OPR