Dimensions & Capacities - Cornelius UF-1 Training Manual

Hide thumbs Also See for UF-1:
Table of Contents

Advertisement

UF-1 and UFB-1 Valves Training Manual
3. OVERVIEW
3.1 Product Description (cont.)
A side water lever kit can be added to a valve allowing for dispensing of water without syrup or concentrate. The side
water lever can be added to either a carbonated drink valve or a non-carbonated drink valve.
Post-mix valves control:
• the ON–OFF of syrup and water,
• the flow rates of syrup and water,
• the mixing of the two ingredients as they pour into 
the cup, and
• in some instances - dispensed portion.
3.2 Dimensions & Capacities
Fast Flow: 1 ½ to 3 oz./sec.
UFB-1: 2 to 4 oz./sec.
Ultra Flow: 3 to 4 ½ oz./sec.
Operational temperature range: 10°C (50°F) to 43°C (110° F)
Voltage requirements: 22 to 27 VAC (50/60 Hz)
Transformer (electronic valves): 80 VA min.
Operating Pressure (flowing): syrup = 20 psi min; water = 35 psi min.
Concentrates and juices that contain particulates must be dispensed from a juice valve.
A slanted drip tray is necessary when using an Optifill
© 2023, Marmon Foodservice Technologies Inc.
Figure 3
valve.
TM
- 4 -
Figure 4
Publication Number: 315222001OPR

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ufb-1

Table of Contents