TECHNICAL SPECIFICATIONS
TECHNOLOGY / PERFORMANCE
Detection mode:
Technology:
Mounting height:
Sensor temperature
range:
ELECTRICAL
Output
Relay 1
Relay 2
Test/Monitoring
input:
Supply voltage:
Power consumption:
Noise:
PHYSICAL
Degree of protection:
COMPLIANCE
FCC certification:
Compliance:
75.5751.12 IXIO-DT1 20230913
Motion
minimum detection speed: 2 in/s
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm
6'6" – 11'6"
local regulations may impact acceptable mounting height (pedestrian applications only)
-13 – 131 °F *
0 – 95% relative humidity, non-condensing
LCD screen is operational from 14 – 131 °F.
The sensor may still be programmed in colder temperatures, but with the remote control.
Electromechanical relay (potential and polarity free)
Max. contact current: 1 A
Max. contact voltage: 30 VAC
Adjustable hold time: 0.5 – 9 s
Solid-state relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 VDC / 30 VAC
Sensitivity:
Low: < 1 V
High: > 10 V (max. 30 V)
Response time on test request: typical < 5 ms
12 – 24 VAC ±10%
12 – 30 VDC ±10%
to be operated from SELV-compatible power supplies only
< 2.5 W
< 70 dB
IP54
FCC: G9B-100606
IC: 4680A-100606
ISO 13849 PL «c» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle)
Presence
typical response time: < 200 ms (max: 500 ms)
Active infrared with background analysis
Spot: 2" × 2" (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2
2
Specifications are subject to change without prior notice.
All values measured in specific conditions.
Page 3 of 12