Download Print this page

Faro mini eterfan Manual page 14

Hide thumbs Also See for mini eterfan:

Advertisement

Remote control
REMOTE CONTROL
The DC brushless motor manual of general type remote control.
THE MANUAL OF TRANSMITTER
THE RECEIVED PROVIDES THE FUNCTION OF MULTIPLICABLE PROTECTION.
1- Lock position: the received has a built–in safety against obstruction during operation. The
motor will be locked operation and disconnected after 30 seconds of interruption. Please
remove obstacles before restart. To reset, simply disable power supply to the fan motor and
restart.
2- Over 80w protection: when the receiver detects power consumption which is greater than
80w, the received power will be stopped and operation will immediately discontinue. Turn
the receiver power on after 5 seconds,
Pairing Transmitter and Receiver – when 2 or more DC ceiling are installed in one location.
When two or more fans are located near each other, you may desire to have the
receiver/transmitter for each fan set to a different code, so that the operation of one fan
does not affect the operation of the other fans.
The DIP switches for the transmitter (remote hand piece) are located in the battery
compartment of the transmitter.
NOTE: Ensure that you have installed an all - poles disconnection switch in the fixed wiring
for each fan, when using DIP code function.
NOTE: Ensure that the power to the Receiver is ON before pairing the transmitter using the
DIP code.
Transmitter/Receiver pairing for ceiling fan 1:
- Turn off both ceiling fans 1 and 2 via the mains supply to the receiver.
- Slide the cover of battery compartment of transmitter to access the DIP switches. This will
be transmitter 1.
- Change the position of the DIP switches in the remote transmitter 1, so that it will be
different to transmitter 2
- Install the 12VDC battery in the compartment. Please make sure the polarity of battery is
correct.
- Turn on the power to receiver 1. Keep the power OFF to receiver 2. (Each ceiling fan must
have its own isolation switch, so that only the Ceiling fan that needs to be paired with the
transmitter will be ON).
- Press and hold the SET button of transmitter 1 for 6 seconds within 60 seconds of switching

Advertisement