Installation of outdoor unit
2. Fix the power connection wire and signal control wire with wire clip (only for
cooling and heating unit).
Note:
Step six: neaten the pipes
1. The pipes should be placed along the wall,
bent reasonably and hidden possibly. Min.
semidiameter of bending the pipe is 10 cm.
2. If the outdoor unit is higher than the wall
hole, you must set a U-shaped curve in the
pipe before pipe goes into the room, in
order to prevent rain from getting into the
room.
Note:
The through-wall height of drain hose
should not be higher than the outlet
pipe hole of indoor unit.
The water outlet cannot be placed
in water in order to drain smoothly.
The water outlet
cannot be placed
in water
the drain hose
cannot raise
upwards.
43
U-shaped curve
drain hose
nwards. The drain hose cannot be
The drain hose cannot be fluctuant
The drain
hose cannot
be fluctuant
wall
The water
outlet cannot
be fluctuant