Safety Instructions For Transportation And Storage - Toyotomi TKG-628R32 User Manual

Wall mounted air conditioner inverter type
Hide thumbs Also See for TKG-628R32:
Table of Contents

Advertisement

Available languages

Available languages

Safety operation of flammable refrigerant
a. Shut down the unit and cut power supply
b. Eliminate the refrigerant
c. Vacuuming
d. Clean it with N2 gas
e. Cutting or welding
f. Carry back to the service spot for welding
The refrigerant should be recycled into the specialized storage tank.
Make sure that there is not any naked flame near the outlet of the vacuum pump
and it is well-ventilated.
Filling the refrigerant
Use the refrigerant filling appliances specialized for R32. Make sure that different
kinds of refrigerant will not contaminate with each other.
The refrigerant tank should be kept upright at the time of filling refrigerant.
Stick the label on the system after filling is finished (or have not finished).
Do not overfilling.
After filling is finished, please do the leakage detection before test running; another
time of leak detection should be done when it is removed.

Safety instructions for transportation and storage

Please use the flammable gas detector to check before unload and open the container.
No fire source and smoking.
According to the local rules and laws.
40 40
GB
GB

Advertisement

Table of Contents
loading

Table of Contents