Integrated Flow Control
Flow Control Setup
1. Install the intrinsically safe flow regulator (FC) as
explained in the ProMix 2KS Installation Manual.
2. Ensure that the analog signal is 0-10 Vdc, or is
properly provided through network communication.
3. Calibrate the system's flow meters; see page 100.
This ensures that the K-factors are tuned to the
range of materials being used.
4. Verify that the I/O inputs are working properly. If
using discrete I/O, check by viewing Advanced
Setup Screen 6 and Advanced Setup Screen 7,
page 42. If using network communication, ensure
the commands are being sent by viewing the Status
Screen, page 24, and Advanced Setup Screen 6
and Advanced Setup Screen 7, page 42, for
inputs.
NOTE: See the Graco Gateway manual for Flow Control
Modbus addresses.
5. See Flow Control Startup.
72
Flow Control Startup
1. Set Flow Control to "On" in Configure Screen 5.
F
. 77. Configure Screen 5
IG
2. In Advanced Setup Screen 1, turn Manual Over-
ride On. The Flow Control Override field will appear.
F
. 78. Advanced Setup Screen 1
IG