ProMix 2KS Integration Specifics
Table 5: ProMix 2KS Digital Inputs (Modbus Register 40040)
Bit
Digital Input Binary
0:5
0 0 0 0 0 0 0 0 0 0 X X X X X X Recipe
6
0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 Color Change
7
0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 Mix
8
0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 Purge
9
0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 Job_Complete Set bit to "1" to initiate Job Complete input (momen-
10
0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 External CC
11
0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 Not Used
12
0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 FC _Calibrate Set bit to "1" to initiate a Flow Control Calibrate input
13
0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 Gun_Trigger
14
0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Reset_Alarm
15
1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Remote Stop
NOTE: Shaded cells relate to the flow charts on pages 55-59.
60
Name
Details
Binary bits for viewing discrete inputs only.
Set bit to "1" to initiate Color Change (momentary)
(CC)
Set bit initiate Mix mode (maintain)
Set bit to "1" to initiate Purge sequence (maintained)
tary)
Set bit to "1" to initiate External Color Change
Ready
(momentary)
(momentary)
Set bit to "1" to indicate the gun is actually triggered
(maintain while gun is triggered, remove when gun is
closed)
Set bit to "1" to clear an active Alarm (momentary)
Set bit to remotely stop unit (momentary)