Table 6: ProMix 2KS Digital Outputs (Modbus Register 40041)
Bit
Digital Input Binary
0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 Purge_CC_Active
1
0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 Mix_Active
2
0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 Mix_Ready
3
0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 CC_Fill_Active
4
0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 FCalActive
5
0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 Flow_Rate_Alarm
6
0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 Special_1
7
0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 Special_2
8
0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 Special_3
9
0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 Special_4
10
0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 Not Used
11
0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 Not Used
12
0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 Alarm_General
13
0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 Alarm_Potlife
NOTE: Shaded cells relate to the flow charts on pages 55-59.
312779E
Name
Get other manuals https://www.bkmanuals.com
ProMix 2KS Integration Specifics
Details
"1" indicates Purge or Color Change is in prog-
ress
"1" indicates Mix is in progress
"1" indicates No Alarms and OK to Mix
"1" indicates the Fill portion of a Color Change is
in progress
"1" indicates the Flow Control Calibrate routine is
in progress
"1" indicates the Flow Rate Alarm/Warning is
active
"1" indicates the Special_1 output is on (monitor
only)
"1" indicates the Special_2 output is on (monitor
only)
"1" indicates the Special_3 output is on (monitor
only)
"1" indicates the Special_4 output is on (monitor
only)
"1" indicates a General Alarm is in process. (If
Mix_Active is still High, then a Warning only.) See
the Modbus charts in the Graco Gateway manual
312785 for details on type.
"1" indicates a Potlife Alarm is in process.