Graco ProMix 2KS Operation page 37

Plural component proportioner
Hide thumbs Also See for ProMix 2KS:
Table of Contents

Advertisement

Setup Mode
Option Screen 2
F
. 38. Option Screen 2
IG
External Color Change
If set to "Off", Color/Catalyst Purge Time and Color/Cat-
alyst Fill Time appear in Advanced Setup Screen 1,
page 39 or Recipe Setup Screen 2, page 44 (depend-
ing on whether Flush and Fill Inputs are set to "Global"
or "Recipe").
If set to "On", these fields are removed from the
screens.
Auto Dump
If the auto dump feature is being used, set to "On". Once
the auto dump is enabled, the gun flush box is enabled
and the potlife alarm is active for 2 minutes, the system
will automatically flush out the old material.
Flow Rate Monitor
This field only appears if Flow Control is set to "Off" in
Configure Screen 5, page 34.
If set to "On," Recipe Setup Screen 6 on page 46 is
added, enabling setting of high and low flow limits.
If set to "Off," flow rate monitoring is disabled and Rec-
ipe Setup Screen 6 on page 46 will not appear.
Solvent Push Enable
To enable the Solvent Push feature, select "Solvent" or
"3rd Valve" (available if 3rd Flush Valve in Configure
Screen 3, page 33, is set to "On").
To disable the Solvent Push feature, set to "Off."
312779E