Electrolux IPro R452a Operator's Manual page 7

Slush machine
Table of Contents

Advertisement

U
-
nscrew the securing bolt (S) in the direction
of the arrow (threading on the left), pull off the
mixing unit (U), and remove the sealing
washers (X) and (T) (see figure 5).
!Caution!
A
void the use of abrasive cleaners which
can damage the finish. Do not put the parts
in a dishwasher.
some parts such as the clear plastic bowls
and auger gears.
T
-
horoughly wash all the removed components
with hot water and mild dishwashing detergent,
but do not use abrasive detergents or powders
that can damage the bowl.
P
-
rovide yourself with a sanitizer suitable for
plastic, rubber and stainless steel objects
S
(
odium hypochlorite 2%), for the US market
bring the approved KAY-5
with a 100ppm dilution (1 Oz packet of KAY-5
+2 ½ gallons of water) (the sanitizing product
shall comply with 40 CFR §180.940).
R
-
inse well and then place all the components
in the sanitizer solution; for proper sanitizing
the parts must remain fully plunged as
recommended by the sanitizer manufacturer
(KAY-5 sanitizer suggest at least 1-2 minutes).
!IMPORTANT!
C
arefully follow the sanitizer producer
prescriptions in terms of time and modes
A
-
fter respecting the correct sanitizing period,
rinse well all the components with clean water
and dry them up with a clean cloth.
T
-
horoughly wash the evaporator and the drip
tray surfaces with a sponge soaked with the
sanitizer (see fig.6).
R
-
epeat all these operations with a clean
sponge soaked with water and carefully dry up
all the surfaces with a clean cloth.
Data di emissione: July, 2023
D
ishwasher may damage
®
Sanitizer/Cleaner
of usage.
®
Revisione: 01
Fig. 5
Fig. 6
Pag. : 7/52

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipro r449Ipro r290

Table of Contents