Troubleshooting Guide - Electrolux IPro R452a Operator's Manual

Slush machine
Table of Contents

Advertisement

NOTE: the following procedures must be performed by a qualified service technician.
Problem
The machine does not cool,
or cools only partially and
the compressor is running
The machine does not cool,
or cools only partially and
the
compressor
is
running
The
machine
over-freeze,
making the auger movement
slow or stopped
The machine is noisy
The main power switch is
"ON" but the unit s not
running
The bowl is leaking
The
dispensing
valve
leaking
Product is flowing into drip
tray through drainage pipe
The auger is not turning
The auger is creating noise
as it rotates
"FILTER"
or
"CUT/OUT"
message
appears
on
Data di emissione: July, 2023

16. TROUBLESHOOTING GUIDE

Possible cause
The
space
inadequate for ventilation
The refrigeration system is working in
DEFROST mode
The condenser filter is clogged with
airborne particles
Fan motor is not running
Refrigerant is leaking
Electrical components of the compressor
are not functioning
not
Some
electrical
complete
The compressor is malfunctioning
No current is coming to the electronic
board
The product brix is too low
The screw setting for the consistency
control system is set too far toward the
"+" position
The limit micro-switch arm is bent away
from
the
gear
contact
The level of the product in the bowl is
too low
The compressor PC board contact don't
open
The fan motor blades are hitting internal
components
The fuses are blown
Some
electrical
complete
The control board is faulty
The gear motor is malfunctioning
One of the bowl seal is not in place
is
The
dispensing
incompletely or incorrectly replaced in its
position
The free movement of the valve is
impeded
Dispensing valve o-rings are damaged
The bell shaped seal between the front of
the cylinder and the auger hub has not
been reinstalled properly
The bell shaped shaft seal or the spindle
bushing seal is damaged or worn
Some
electrical
complete
The control board is faulty
The gear motor is malfunctioning
The bell shaped shaft seal has been
replaced
without
damaged
The auger has been incompletely or
incorrectly reassembled
The filter is dirty and needs to be
the
cleaned
around
the
machine
connections
are
motor
and
prevents
connections
are
valve
has
been
connections
are
lubrication
or
Revisione: 01
Solution
is
Allow at least 20cm between the
machine and anything next to it;
keep it away from heat sources
Return to FREEZE mode
Clean the filter
Check the fan motor's electrical
connections and, if disconnected,
reconnect. If still not operating,
replace the motor
Locate the leak, eliminate it and
recharge the system
Replace
the
components
not
Check the contacts and correct
those incomplete
Replace the compressor
Check the electrical connections
to the pc board as well as the
transformer
board and correct
Check
the
correct
Reset the screw toward the "-"
position to produce a thinner
consistency product
Using pliers, straighten the limit
switch arm
Add more product or turn the
refrigeration "Off"
Replace the PC board
Check and correct
Replace the fuses
not
Check the contacts and correct
those incomplete
Replace the control board
Replace the gear motor
Replace or reposition the seal
Reassemble and replace
Clean and lubricate the valve
and the valve cylinder with the
lubricant
provided
machine
Replace the o-rings
Find the seal and put it back in
place
Replace the damaged/worn seal
and check the condition of the
drive shaft
not
Check the contacts and correct
those incomplete
Replace the control board
Replace the gear motor
Replace or clean and lubricate
is
with the lubricant provided with
the machine
Check and correct
Clean and replace filter following
instructions
Pag. : 26/52
malfunctioning
feeding
the
PC
product
brix
and
with
the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipro r449Ipro r290

Table of Contents