"FILTER CLEANING" Alarm
A filter cleaning alarm will activate when the
unit is running hot due to insufficient internal air
circulation. When this occurs the FILTER
message will start blinking on the capacitive
display as shown in picture 22.
To determine the condition that caused the
alarm, see list of conditions below:
Condition A: the filter is dirty and needs to
be cleaned.
Corrective Action: clean and replace filter
following instructions(Removing and
Cleaning Filter).
Condition B: the unit is positioned too close
to a wall or other object restricting air flow
and causing the machine to run at a higher
temperature.
Corrective Action: reposition unit to
maximize ventilation space (Installation
Instructions).
Condition C: the unit has been installed near
a heat source, causing the machine to run at
a high temperature (installation near a heat
source should be avoided).
Corrective Action: reposition unit to
maximize ventilation space.
"SYSTEM OVER TEMPERATURE" alarm
A system over temperature message CUT/OUT
will appear (fig.23) as a safety precaution when
the unit has overheated to protect the
compressor.
The system automatically goes to "OFF"
status where the compressor's operations is
stopped, while augers will keep working to
avoid forming ice blocks.
When this occurs a CUT/OUT message will
appear on capacitive display to alert the
operator of this condition (fig.23).
When this alarm activates, turn off all
switches. Then determine the condition and
the necessary corrective action.