ABB Tina 3A Product Manual page 15

Adapter unit
Table of Contents

Advertisement

Power output (Tina 3Aps only)
Source current
General
Protection class
Ambient temperature
Humidity range
Housing material
Connectors
Cables
Tightening torque
Size (L x W x H)
Weight
Color
Directives / Harmonized standards
Conformity
IEC/EN 61508-1...7
EN 62061
EN ISO 13849-1
Certificates
Information for use in USA/Canada
Pollution degree
Altitude
Humidity
Indoor use statement
2TLC172125M0201 Rev.F
Maximum: 1 A
IP67
Operation: -10 to +55 °C
Storage: -30 to +70 °C
35 to 85 % (with no icing or condensation)
TPU
M12 5-pole male connector
Conductor cross section area: 0.34 mm
Length: 300 mm
Insulation: PVC
Conductor material: Tinned stranded copper
M12 connector: 0.6 Nm
M20 nut: 2-2.3 Nm
56 x 27 x 24 mm
~ 30 g
Black
European Machinery Directive 2006/42/EC
EN ISO 12100:2010
EN 62061:2005+Cor.:2010+A1:2013+A2:2015
EN ISO 13849-1:2015
EN 60204-1:2018
-9
SIL3, PFH
= 4.50·10
D
SIL3
PL e, category 4
TÜV Nord, cCSAus
2
2000 m (max)
80% max for temperatures up to 31 °C
For indoor use only
2
(AWG 22)