Power output (Tina 3Aps only)
Source current
General
Protection class
Ambient temperature
Humidity range
Housing material
Connectors
Cables
Tightening torque
Size (L x W x H)
Weight
Color
Directives / Harmonized standards
Conformity
IEC/EN 61508-1...7
EN 62061
EN ISO 13849-1
Certificates
Information for use in USA/Canada
Pollution degree
Altitude
Humidity
Indoor use statement
2TLC172125M0201 Rev.F
Maximum: 1 A
IP67
Operation: -10 to +55 °C
Storage: -30 to +70 °C
35 to 85 % (with no icing or condensation)
TPU
M12 5-pole male connector
Conductor cross section area: 0.34 mm
Length: 300 mm
Insulation: PVC
Conductor material: Tinned stranded copper
M12 connector: 0.6 Nm
M20 nut: 2-2.3 Nm
56 x 27 x 24 mm
~ 30 g
Black
European Machinery Directive 2006/42/EC
EN ISO 12100:2010
EN 62061:2005+Cor.:2010+A1:2013+A2:2015
EN ISO 13849-1:2015
EN 60204-1:2018
-9
SIL3, PFH
= 4.50·10
D
SIL3
PL e, category 4
TÜV Nord, cCSAus
2
2000 m (max)
80% max for temperatures up to 31 °C
For indoor use only
2
(AWG 22)
1 5