Page 1
— SA F E T Y PR OD U CTS Tina 10A/B/C Adapter unit Product Manual 2TLC010042M0201 Rev.C ORIGINAL INSTRUCTIONS new.abb.com/low-voltage/products/safety-products...
Page 2
Suitability for use ABB shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product. Third party certificates for the products are available at https://new.abb.com/low- voltage/products/safety-products.
This document is intended for authorized personnel. Reading prerequisites It is assumed that the reader of this document has knowledge of the following: • Basic knowledge of ABB safety products • Knowledge of machine safety Special notes Pay attention to special notes in the document:...
Safety Safety precautions The safety precautions must be followed during installation, operation, maintenance and troubleshooting. It is the responsibility of the user to ensure the correct overall functionality. Warning! Carefully read through the entire product manual before using the device. Warning! The devices shall be installed by authorized personnel following applicable Safety regulations, standards and the Machinery directive.
DYNlink safety circuit monitored by a safety controller or a safety PLC. Tina 10A, Tina 10B and Tina 10C are used to adapt light beams and light curtains with OSSD outputs to the DYNlink safety circuit. This also enables complete external interconnections using cables with M12 connectors only, which reduces the cabling to and connections in the apparatus enclosure.
Installation • Attach the cable or device to the M12 connector on Tina. • Gently hold the Tina unit to the mounting surface and attach the unit using an M4 bolt. • See max. tightening torques in chapter “Technical data”. Installation precautions Warning! All safety functions shall be tested before starting up the system.
C) Orion Receiver A) Smile D) Orion Transmitter B) Safety controller/Safety PLC C) Orion Receiver A) Smile M12 8-pole female, Tina 10 A/B/C M12 5-pole female, Tina 10B White Tina 10A/10C: +24 VDC Brown +24 VDC Tina 10B: Test/Reset White...
Page 9
ABB web. Note! Which cable to use between Orion and Tina 10A/B/C is depending on Orion model used – see product catalog on ABB web. Warning! Information output signals shall never be used for safety purpose(s). Warning! The OSSD connections shall not be used for purposes other than intended.
Functions LED Indications LED indication Description DYNlink state Green Safety inputs ON (protection OK) DYNlink signal Green/red flashing Safety inputs ON (protection OK) 0 VDC, DYNlink interrupted before this unit Safety input OFF 0 VDC or DYNlink signal Safety inputs at any state +24 VDC connected to DYNlink signal input (pin-2) or interrupted in this unit...
Warning! The safety functions and the mechanics shall be tested regularly, at least once every year to confirm that all the safety functions are working properly. Warning! In case of breakdown or damage to the product, contact ABB. Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, impairing the safety of the device which in turn could lead to serious injury to personnel.
Troubleshooting LED indications LED indication Probable cause Action Device interrupted Check status of the device. Bad connection to the Check cable to the light beam and device fasten carefully. +24 VDC connected to Check if there is +24 VDC on DYNlink signal input DYNlink signal input (pin-2).
SE-721 61 Västerås Sweden Order code/Ordering data 2TLA020054R1210: Tina 10A v2 Adapter unit 2TLA020054R1310: Tina 10B v2 Adapter unit 2TLA020054R1610: Tina 10C v2 Adapter unit Power supply (Orion supply excluded) Required power supply type PELV/SELV, not intended to be connected to a DC distribution network.
Page 16
Housing material Connectors Tina 10A v2: M12 8-pole female, M12 5-pole male Tina 10B v2: M12 8-pole female, M12 5-pole female, M12 5-pole male Tina 10C v2: M12 8-pole female, M12 5-pole female, M12 5-pole male Tightening torque M12 connector: 0.6 Nm...
Need help?
Do you have a question about the Tina 10B and is the answer not in the manual?