Troubleshooting; Manual Test Mode; Manual Test Mode Commands - Motorola C25 Series Service Manual

Dual band wireless telephone
Hide thumbs Also See for C25 Series:
Table of Contents

Advertisement

Troubleshooting

Troubleshooting

Manual Test Mode

Manual Test Mode Commands

Table 4. Test Commands
Test Command
*#300# OK
*#301# OK
*#302# OK
#303# OK
*#307# OK
#400# OK
*#402# OK
*#403# OK
1998 0722 OK
1. Use with care - Contains calibration factors
34
Motorola PF C25 telephones are equipped with a manual test mode capability. This
allows service personnel to verify functionality and perform fault isolation by
entering keypad commands.
To enter the manual test command mode, a GSM / DCS test SIM must be used.
Press , to turn the phone OFF.
1.
2.
Remove the battery as described in the procedures.
3.
Remove the customer's SIM card from the phone as described in the proce-
dures.
4.
Insert the test SIM into the SIM slot.
5.
Replace the battery as described in the procedures.
Press , to turn the phone ON.
6.
7.
Press and hold the # button for approximately 3 seconds until TEST displays
on the screen. The phone may now be issued test commands listed in Table 4.
List Software and Hardware version
Full keypad functional test
1
Acoustic Test
1 - Greeting
2 - Main Volume Gain
3 - Input Cal
4 - Output Cal
5 - Side In Gain
6 - Vox Gain
7 - Min Mic Energy
8 - More
(a) - In Volume Gain
(b) - Aux Volume Gain
(c) - Silence Prd
(d) - Supp Prd
(e) - In Volume
(f) - Out Volume
(g) - Icon
(h) - Image
(i) - Animation
1
Settings Saved
Engineering Test Mode
1
ADC, Cal val
Adjust display Intensity/Contrast
List the Manufacturing Information
Master Unlock code for Phone and Sim Lock
October 14, 2002
Test Function/Name
Product Family C25
6881041B25

Advertisement

Table of Contents
loading

This manual is also suitable for:

C300