Download Print this page
Cecilware APT18P Manual

Cecilware APT18P Manual

Pourover coffee brewer

Advertisement

Quick Links

Cecilware sells value... Worldwide
43 -05 20th Avenue, Long Island City, NY 11105
TEL
718-932-1414
FAX
718-932-7860
APT18P
POUROVER COFFEE BREWER
MANUAL
• Specifications................................................
• Installation, Start-Up, Operating Instructions
• Cleaning....................................................
• Adjustments & Troubleshooting...................
• Parts Identification.........................................
• Wiring Diagrams ........................................... 7
2
2
3
4
5
NL72A

Advertisement

loading

Summary of Contents for Cecilware APT18P

  • Page 1 MANUAL • Specifications....……………………….. • Installation, Start-Up, Operating Instructions • Cleaning……………………………………………. • Adjustments & Troubleshooting………………. • Parts Identification....……………………... • Wiring Diagrams …....……………………. 7 Cecilware sells value... Worldwide 43 -05 20th Avenue, Long Island City, NY 11105 • 718-932-1414 • 718-932-7860 NL72A...
  • Page 2: Specifications

    SPECIFICATIONS MODEL VOLTS TOTAL KW AMPS C-2001P 8.00 17.35 17.25 WARNING: MACHINE WARRANTY IS VOID IF MACHINE IS CONNECTED TO ANY VOLTAGE OTHER THAN 120 VOLTS. (EXPORT UNITS SHOULD BE CONNECTED TO 220 VOLTS) ** INSTALLATION INSTRUCTIONS ** NOTE: a separate circuit should be supplied for each of these brewers with a 15 amp circuit breaker or fuse.
  • Page 3 ** CLEANING INSTRUCTIONS ** 1. Wash Brew Funnel and Air Pot by hand as needed. Do not use dishwasher, which may cause Air Pot breakage. 2. For cleaning all metal surfaces, use any reputable stainless steel cleaning compound. Spray head should be checked and cleaned regularly. (At least once a week.) Spray head holes must be kept open.
  • Page 4: Thermostat Adjustments

    **SERVICE INSTRUCTIONS** and **TROUBLE SHOOTING GUIDE** FOR AUTHORIZED SERVICE PERSONNEL ONLY CAUTION: DISCONNECT POWER BEFORE ATTEMPTING ANY ELECTRICAL REPAIRS. THERMOSTAT ADJUSTMENTS: NOTE: The thermostat is behind the lower front panel. If water temperature is less than 197 degrees F (92 degrees C) slowly turn thermostat knob clockwise until ready light goes out. When temperature of water approaches 197 degrees to 203 degrees F (92 degrees to 95 degrees C) slowly turn thermostat knob counterclockwise until the green ready light comes on.
  • Page 5 ** PARTS IDENTIFICATION ** ITEM PART DESCRIPTION NUMBER SO91Q BODY FRAME ASSEMBLY SI64A FRONT TOWER COVER V223A AIR POT, 2.2 liters (NOT INCLUDED WITH BREWER) L217A POWER SWITCH, RED, ROCKER C072A READY LIGHT, GREEN NL68A LABEL V000A BREW FUNNEL, BLACK L069A HEATER SWITCH U810C...
  • Page 6 FRONT VIEW – OPEN TOP VIEW - OPEN ITEM PART NUMBER DESCRIPTION L681A THERMOSTAT ASS’Y B171A TERMINAL BLOCK RK48Q TANK ASS’Y K525A SS ELBOW TUBE (2) M611A SILICONE TUBE, .5 ID, WATER INLET & DRAIN L069A HEATER SWITCH RQ74A TANK TOP G296A HEATER ELEMENT 120V, 1500 W L573A...

This manual is also suitable for: