Inta BUFF25 Installation And Maintenance Instructions Manual

Insulated buffer vessel

Advertisement

Quick Links

Insulated Buffer Vessel
BUFF25, BUFF50, BUFF80 & BUFF100
Installation and Maintenance Instructions
Intatec Ltd
Airfield Industrial Estate
Hixon
Staffordshire
ST18 0PF
In this procedure document we have endeavoured to make the informa-
Tel: 01889 272 180
tion as accurate as possible.
Fax: 01889 272 181
We cannot accept any responsibility should it be found that in any
email: sales@intatec.co.uk
respect the information is inaccurate or incomplete or becomes so as a
web: www.intatec.co.uk
result of further developments or otherwise.
© Intatec Ltd 2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BUFF25 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Inta BUFF25

  • Page 1 Insulated Buffer Vessel BUFF25, BUFF50, BUFF80 & BUFF100 Installation and Maintenance Instructions Intatec Ltd Airfield Industrial Estate Hixon Staffordshire ST18 0PF In this procedure document we have endeavoured to make the informa- Tel: 01889 272 180 tion as accurate as possible.
  • Page 2 Introduction This installation document has been prepared for the Inta range of insulated buffer vessels, 25 to 100 litre capacity. Buffer vessels are designed to store a volume of water to help optimize system efficiency and reduce pump short cycling. Buffer vessels also help to provide hydraulic separation between circuits.
  • Page 3 Dimensions 25 litre with bracket for wall mounting ØD Volume ØD litres G¾ 1008 G¾ G1¼ G1¼ 1071 G1¼ G1¼ © Intatec Ltd 2023...
  • Page 4 Preparation for installation Access: Ensure safe access to allow the transportation of the buffer vessel to it's intended location and adequate lighting is available. Tools: Ensure the correct tools and consumables are available for the installation before commencing. Handling and Lifting: Manual handling of large or heavy equipment may present a risk of injury.
  • Page 5 Typical Application Buffer vessel Heat To the heating system source Pump Pump Maintenance No maintenance as such is required. Periodically check for signs of leakage from the buffer vessel or from the joints. Check the outer casing for signs of damage or damage to the insulation. An occasional wipe to remove dust from the casing is recommended.
  • Page 6 Notes: © Intatec Ltd 2023...
  • Page 7 Notes: © Intatec Ltd 2023...
  • Page 8 Please leave this Manual for the User To activate your product warranty please visit www.intatec.co.uk and click on Product Registration Intatec Ltd Airfield Industrial Estate Hixon Staffordshire ST18 0PF Tel: 01889 272 180 Fax: 01889 272 181 email: sales@intatec.co.uk web: www.intatec.co.uk E &...

This manual is also suitable for:

Buff50Buff80Buff100