Double3 Derby LED Q6
Problem
Probable cause(s)
No power to the fixture
One or more
fixtures do not
function at all
Primary fuse blown
Fixture is too hot
No light or LEDs
cuts out
intermittently
LEDs damaged
The power supply settings do not
match local AC voltage and
frequency
Product Specifications
Model:
Input Voltage:
Power consumption:
Protection rate:
Fuse:
Dimensions:
Weight:
Electro-mechanical effects:
Light source:
Drive current
Connections:
Housing:
Music activated colour changer effect
Sound-controlled through a built-in
microphone
Plug & Play
Max. ambient temperature t
Max. housing temperature t
Minimum distance:
Minimum distance from flammable surfaces:
Minimum distance to lighted object:
Design and product specifications are subject to change without prior notice
j
Ordercode: 43160
Showtec Double3 Derby LED Q6
100-240V AC, 50/60Hz
20W
IP-20
1A/250V
310 mm x 315 mm x 270 mm (LxWxH) (incl. bracket)
3,6 kg
2 x 12W LED (Red, Green, Blue, Cyan, Amber, White)
700mA
IEC connectors (IN/OUT)
Black Iron
:
40°C
a
:
80°C
B
0,5 m
1 m
Website:
www.Showtec.info
Email:
service@highlite.nl
Solution
•
Check if power is switched on and
cables are plugged in
•
Replace fuse
•
Allow the fixture to cool down
•
Clean the fan
•
Make sure air vents in control
panel and the front lens are not
blocked
•
Turn up the air conditioning
•
Disconnect the fixture and return it
to your dealer
•
Disconnect fixture. Check settings
and correct if necessary
9