Problem
The induction hob
or a cooking zone
has turned itself off
unexpectedly, a tone
sounds and an error
code is displayed
(typically alternating
with one or two digits
in the cooking timer
display).

8. FAILURE DISPLAY AND INSPECTION

The induction hob is equipped with a self diagnostic function. With this test the technician is able to check
the function of several components without disassembling or dismounting the hob from the working
surface.

Troubleshooting

1) Failure code occur during customer using & Solution;
Failure code
Ceramic plate temperature sensor failure-
E1
-open circuit.
Ceramic plate temperature sensor failure-
E2
-short circuit.
Eb
Ceramic plate temperature sensor failure
E3
High temperature of ceramic plate sensor.
Temperature sensor of the IGBT failure
E4
--open circuit.
Temperature sensor of the IGBT failure
E5
--short circuit
Copyright © 2019, Fast ČR, a. s.
Possible causes
Technical fault.
Problem
Auto-Recovery
What to do
Please note down the error letters
and numbers, switch the power to
the induction hob off at the wall, and
contact a qualified technician.
Solution
Check the connection or replace the
ceramic plate temperature sensor.
Wait for the temperature of ceramic plate
return to normal.
Touch "ON/OFF" button to restart unit.
Replace the power board.