ALTV2416UL3 Series
CCTV Power Supplies with
Factory installed 3-wire line cord
Models Include:
ALTV2416ULX3
- 24VAC @ 7A (170VA)
or 28VAC @ 6A (170VA).
- Sixteen (16) Fuse Protected Outputs.
ALTV2416300UL3
- 24VAC @ 7A (175VA)
or 28VAC @ 6.25A (175VA).
- Eight (8) Fuse Protected Outputs.
ALTV2416300ULM3
- 24VAC @ 12.5A (300VA)
or 28VAC @ 10A (280VA).
- Sixteen (16) Fuse Protected Outputs.
ALTV2416600UL3
- 24VAC @ 25A (600VA)
or 28VAC @ 20A (560VA).
- Sixteen (16) Fuse Protected Outputs.
Installation Guide
Rev. 040506
Installing Company: _______________ Service Rep. Name: __________________________________
Address: _____________________________________________ Phone #: __________________
ALTV2416ULCBX3
- 24VAC @ 7A (170VA)
or 28VAC @ 6A (1705VA).
- Sixteen (16) PTC Protected Outputs.
ALTV2416300ULCB3
- 24VAC @ 12.5A (300VA)
or 28VAC @ 10A (280VA).
- Sixteen (16) PTC Protected Outputs.
ALTV2416300ULCBM3
- 24VAC @ 12.5A (300VA)
or 28VAC @ 10A (280VA).
- Sixteen (16) PTC Protected Outputs.
ALTV2416600ULCB3
- 24VAC @ 25A (600VA)
or 28VAC @ 20A (560VA).
- Sixteen (16) PTC Protected Outputs.
More than just power.
TM

Advertisement

loading
Need help?

Need help?

Do you have a question about the ALTV2416UL3 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Altronix ALTV2416UL3 Series

  • Page 1 ALTV2416UL3 Series CCTV Power Supplies with Factory installed 3-wire line cord Models Include: ALTV2416ULX3 ALTV2416ULCBX3 - 24VAC @ 7A (170VA) - 24VAC @ 7A (170VA) or 28VAC @ 6A (170VA). or 28VAC @ 6A (1705VA). - Sixteen (16) Fuse Protected Outputs.
  • Page 2: Specifications

    Overview: Altronix ALTV2416UL3 Series CCTV Power Supplies provide 24VAC or 28VAC distributed via sixteen (16) fuse or PTC protected outputs for powering CCTV cameras, heaters and other video accessories. Sixteen (16) Output ALTV2416UL3 Reference Chart: Altronix Model Number 24VAC 3.5A/ ALTV2416ULX3 –...
  • Page 3: Installation Instructions

    Chart, pg. 2). Terminal Identification: PD8/PD8CB - Distribution Module 1P - 8P AC output. 1N - 8N AC output. PD16W/PD16WCB - Distribution Module 1P - 16P AC output. 1N - 16N AC output. ALTV2416UL3 Series Installation Guide - 3 -...
  • Page 4 Class 1 Outputs Class 1 Outputs MAIN FUSE non power-limited Primary Primary In-line Fuse In-line Fuse White Lead Black Lead Voltage Selection Configuration Input 115VAC, 50/60Hz 24VAC Output (Yellow) (Black) 28VAC Output (Black) (Yellow) - 4 - ALTV2416UL3 Series Installation Guide...
  • Page 5 Class 3 Wet 28VAC configuration Class 1 MAIN FUSE non power-limited Primary Primary In-line Fuse In-line Fuse White Lead Black Lead Voltage Selection Configuration Input 115VAC, 50/60Hz 24VAC Output (Yellow) (Black) 28VAC Output (Black) (Yellow) ALTV2416UL3 Series Installation Guide - 5 -...
  • Page 6 8P & N for outputs 2 through 8) Fig. 3a Green Lead (ground) Illuminated Power Disconnect Circuit Breaker with manual reset Voltage Selection Configuration Input 115VAC, 24VAC 50/60Hz Output (Yellow) (Black) 28VAC Output (Black) (Yellow) - 6 - ALTV2416UL3 Series Installation Guide...
  • Page 7 8P & N for outputs 2 through 8) Fig. 4a Green Lead (ground) Illuminated Power Disconnect Circuit Breaker with manual reset Voltage Selection Configuration Input 115VAC, 24VAC 50/60Hz Output (Yellow) (Black) 28VAC Output (Black) (Yellow) ALTV2416UL3 Series Installation Guide - 7 -...
  • Page 8 Fig. 6 - ALTV2416300ULCBM3 Illuminated Power Disconnect Circuit Breaker with manual reset Fig. 6a 4 5 6 7 8 12 13 COMMON OUTPUTS PROTECTED OUTPUTS Transformer underneath power distribution board 3.5A/250V Input 115VAC, 50/60Hz - 8 - ALTV2416UL3 Series Installation Guide...
  • Page 9 Follow same procedure using terminals 2P & N through 8P & N for outputs 2 through 8) MAIN FUSE Green Lead (ground) White Lead Black Lead Voltage Selection Configuration 24VAC Input 115VAC, 50/60Hz Output (Yellow) (Black) 28VAC Output (Black) (Yellow) ALTV2416UL3 Series Installation Guide - 9 -...
  • Page 10 Follow same procedure using terminals 2P & N through 8P & N for outputs 2 through 8) MAIN FUSE Green Lead (ground) White Lead Black Lead Voltage Selection Configuration Input 115VAC, 24VAC 50/60Hz Output (Yellow) (Black) 28VAC Output (Black) (Yellow) - 10 - ALTV2416UL3 Series Installation Guide...
  • Page 11 8.5” x 7.5” x 3.875” (215.9mm x 191mm x 98.4mm) 3.63” (92.2mm) 1.25” (31.75mm) 7.25” (184.15mm) 1.25” (31.75mm) 0.6” (15.24mm) 0.6” (15.24mm) 1.25” (31.75mm) 1.25” (31.75mm) 0.6” (15.24mm) 0.6” (15.24mm) 3.85” (97.79mm) 1” (25.4mm) 1” (25.4mm) ALTV2416UL3 Series Installation Guide - 11 -...
  • Page 12 1.0” 1.0” 10.5” (266.7mm) (25.4mm) (25.4mm) Altronix is not responsible for any typographical errors. –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IIALTV2416UL3 Series L02U...