Altronix ALTV2416300M Installation Manual
Altronix ALTV2416300M Installation Manual

Altronix ALTV2416300M Installation Manual

Altv2416 series cctv power supplies
Hide thumbs Also See for ALTV2416300M:

Advertisement

ALTV2416 Series
CCTV Power Supplies

Installation Guide

Models Include:
• ALTV2416
- 24VAC @ 8 amp (200VA).
or 28VAC @ 7 amp.
- Sixteen (16) Fuse Protected Outputs.
• ALTV2416350
- 24VAC @ 14 amp (350VA)
or 28VAC @ 12.5 amp (350VA).
- Sixteen (16) Fuse Protected Outputs.
• ALTV2416300M
- 24VAC @ 12.5 amp (300VA)
or 28VAC @ 10 amp (300VA).
- Sixteen (16) Fuse Protected Outputs.
• ALTV2416600
- 24VAC @ 28 amp (700VA)
or 28VAC @ 25 amp (700VA).
- Sixteen (16) Fuse Protected Outputs.
• ALTV2416CB
- 24VAC @ 8 amp (200VA).
or 28VAC @ 7 amp.
- Sixteen (16) PTC Protected Outputs.
• ALTV2416350CB
- 24VAC @ 14 amp (350VA)
or 28VAC @ 12.5 amp (350VA).
- Sixteen (16) PTC Protected Outputs.
• ALTV2416300CBM
- 24VAC @ 12.5 amp (300VA)
or 28VAC @ 10 amp (300VA).
- Sixteen (16) PTC Protected Outputs.
• ALTV2416600CB
- 24VAC @ 28 amp (700VA)
or 28VAC @ 25 amp (700VA).
- Sixteen (16) PTC Protected Outputs.
Rev. 021804

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALTV2416300M and is the answer not in the manual?

Questions and answers

Summary of Contents for Altronix ALTV2416300M

  • Page 1: Installation Guide

    28VAC @ 12.5 amp (350VA). or 28VAC @ 12.5 amp (350VA). - Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs. • ALTV2416300M • ALTV2416300CBM - 24VAC @ 12.5 amp (300VA) - 24VAC @ 12.5 amp (300VA) or 28VAC @ 10 amp (300VA).
  • Page 2: Specifications

    Overview: These Altronix CCTV Power Supplies provide 24VAC/28VAC distributed via sixteen (16) fuse or PTC protected outputs for powering CCTV Cameras, heaters and other video accessories. Sixteen (16) Output ALTV2416 Reference Chart: Altronix Model Number 24VAC 8 amp ALTV2416 3.5 amp 5 amp/250V 1.9 amp...
  • Page 3: Installation Instructions

    Installation Instructions: 1. Mount unit in desired location. 2. Slide switch on PD board to OFF position for models ALTV2416 and ALTV2416CB (Fig. 1, pg. 4). Turn OFF main switch on all other models (Figs. 2-4, pgs. 4-6). 3. All units are factory set for 24VAC operation. For 28VAC operation, adjust unit prior to mounting and applying power as follows: Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and the yellow wire [24V] is connected to the terminal marked [S].
  • Page 4 Fig. 1 - ALTV2416 • ALTV2416CB Back Panel of Enclosure Enclosure Door Used on PTC Models (example: ALTV2416CB) F U S E D P O W E R O U T P U T S F U S E D P O W E R O U T P U T S F U S E D...
  • Page 5 Fig. 3 ALTV2416300M • ALTV2416300CBM Power Switch Used on PTC Models (example: ALTV2416300CBM) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16...
  • Page 6 Fig. 4 ALTV2416600 • ALTV2416600CB Used on PTC Models (example: ALTV2416600CB) 24VAC or 28VAC fused output 1 (Follow same procedure using terminals 2P & N through 8P & N fused outputs 2 through 8) MAIN FUSE Power Switch 24VAC Output (Factory Set) 28VAC Output 115VAC input,...
  • Page 7 Enclosure Dimensions for: • ALTV2416 • ALTV2416CB TOP ONLY 8.5"H x 7.5"W x 3.5"D Enclosure Dimensions for: 3.625” • ALTV2416300M • ALTV2416300CBM 1.25” 8.5"H x 7.5"W x 3.75"D 3.85” 7.25” 1.25” 6.05” 0.50” 1.00” 1.00” 6.825” 8.125” 1.75” 1.00” 1.00”...
  • Page 8 11.66" 12.1" 13" Altronix is not responsible for any typographical errors. Altronix Corp. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. II1ALTV2416Series B09E MEMBER - 8 -...