Processor And Heat Sink Module; Removing A Heat Sink - Dell PowerEdge C6615 Installation And Service Manual

Table of Contents

Advertisement

Figure 51. Installing a memory module
Next steps
1. Follow the procedure listed in
2. To verify that the memory module has been installed properly, press F2 during reboot and navigate to System Setup Main
Menu > System BIOS > Memory Settings. In the Memory Settings screen, the System Memory Size must reflect the
updated capacity of the installed memory.
3. If the System Memory Size is incorrect, one or more of the memory modules may not be installed properly. Shut down the
system and ensure that the memory modules are firmly seated in the correct sockets.
4. Run the system memory test in system diagnostics.

Processor and heat sink module

This is a service technician replaceable part only.

Removing a heat sink

Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3.
Remove the air
shroud.
NOTE:
The heat sink and processor are too hot to touch for some time after the system has been powered down. Allow
the heat sink and processor to cool down before handling them.
Steps
1. Using a Torx T20 screwdriver, fully loosen the captive screw all the way before moving to the next screw (on one-screw-at-
a-time basis).
NOTE:
Follow the screw sequence defined on the heat sink label. Disassembly order: 4, 3, 2, 1
NOTE:
The captive screw numbers are marked on the heat sink.
2. Lift the heat sink from the system.
After working inside your
Safety
instructions.
Before working inside your
system.
system.
Installing and removing system components
79