Feider Machines FGHI3500RS User Manual

Feider Machines FGHI3500RS User Manual

Petrol inverter generator

Advertisement

Quick Links

ORIGINAL INSTRUCTIONS >EN
PETROL INVERTER GENERATOR
LOW POWER GENERATING SET
FGHI3500RS
USER GUIDE
CAUTION: Read this manual before using this machine!

Advertisement

Table of Contents
loading

Summary of Contents for Feider Machines FGHI3500RS

  • Page 1 ORIGINAL INSTRUCTIONS >EN PETROL INVERTER GENERATOR LOW POWER GENERATING SET FGHI3500RS USER GUIDE CAUTION: Read this manual before using this machine!
  • Page 2: Table Of Contents

    CONTENTS 1. SAFETY INSTRUCTIONS........................... 3 2. QUICK START............................... 7 3. SAFETY LABEL POSITION..........................8 4. PARTS IDENTIFICATION............................9 5. CHECK BEFORE OPERATION........................10 6. START THE ENGINE............................12 7. OPERATING THE GENERATOR........................14 8. SHUT OFF THE ENGINE..........................18 9. MAINTENANCE..............................19 10.
  • Page 3: Safety Instructions

    1. SAFETY INSTRUCTIONS WARNING 1. Attention! Exhaust gases are toxic. Do not operate the generator in a room without ventilation system! 2. Children should be protected by keeping them at a safe distance from the generator set! 3. Refilling of the generating sets are not allowed during the operation! 4.
  • Page 4  Keep the fuel filter clean, and change the oil of the motor regularly.  Periodically check the installation of the connections and the tightness of the fixations, re-tightening them if necessary.  Clean the components of the air filter periodically, and replace the air filter when necessary. ...
  • Page 5  Always stop the motor of the generator when filling it with fuel.  Never fill the fuel tank while smoking or near a naked flame.  Make sure you don’t spill fuel on the motor and the exhaust grille of the generator during filling with fuel.
  • Page 6 Symbol Attention! Please read the manual carefully before using the unit! Conforms to relevant safety standards Do not dispose of old appliances with domestic rubbish . Guaranteed sound power level Ground connection Fill in engine oil It is forbidden to run the generator in an enclosed room because exhaust emissions can lead humans or animals to coma to death.
  • Page 7: Quick Start

    2. QUICK START WARNING Only use outdoors. The generator emits carbon monoxide, a toxic colorless and odorless gas  that can cause death or serious injury. Ensure that the generator is placed horizontally.  Never work in the rain, snow or other humid environment. ...
  • Page 8: Safety Label Position

    When not using the generator for a long time, please turn off the generator. Foreword Thank you for purchasing our Inverter generator This manual includes the operation and maintenance of Model FGHI3500RS series inverter generator. All contents of this manual are consistent with the latest products (when this manual is printed).
  • Page 9: Parts Identification

    4. PARTS IDENTIFICATION...
  • Page 10: Check Before Operation

    Control Panel 5. CHECK BEFORE OPERATION The generator should be placed on a flat ground, with no debris around, and at least 1 meter away from buildings and other equipment. BE CAUTIOUS  Be sure to check whether the generator is placed horizontally, and the engine is off. Check the Oil Level BE CAUTIOUS ...
  • Page 11 BE CAUTIOUS  Operation of the engine with insufficient engine oil may cause serious damage to the engine.  The oil alert system automatically shuts down the engine before the oil level drops to safety line. To avoid the accidentally shutdown, we recommend that you check the oil level regularly. Check the Fuel Level Use automotive gasoline (preferably unleaded or low-lead gasoline to reduce combustion chamber carbon and reduce environmental pollution).
  • Page 12: Start The Engine

    Check the Air Filter Check the air filter core to make sure it's clean and the performance is as normal.  Remove the air filter cover screws and remove the air filter cover.  Draw the air filter box drawer as shown below. ...
  • Page 13  Pull outward the throttle cable.  Pull the handle until your feel resistance, then pull the handle as the direction of the arrow shown below to start the generator. BE CAUTIOUS  Never allow the starting handle to rebound. Slowly put it back. ...
  • Page 14: Operating The Generator

    BE CAUTIOUS  If the main jet is designed for high altitude areas but is operating at low altitudes, it may cause decreased output power, overheating, or serious engine damage due to thin air-fuel mix. 7. OPERATING THE GENERATOR WARNING ...
  • Page 15 Use of AC Power  Connect the ground bolt.  Start the engine in accordance with the “Start the Engine” requirements.  Make sure the connected device is turned off, then connect the device to the generator.  When the power indicator (green) is on, turn on the connected device. BE CAUTIOUS ...
  • Page 16 When using the generator with a pure inductive load, the pure inductive load cannot exceed the rated power of the generator. The power can only run 40% to 75% of rated power on pure inductive load. Model FGHI3500RS Rated Power (W) 3000 Frequency(Hz)...
  • Page 17 For example: When the rated power of the generator is PN = 3.0KW, the altitude is 1000m, the ambient temperature is 35℃, the relative humidity is 80%. Under these circumstances, the rated output of the generator is P=PN×(C-0.02)=3.0×(0.77-0.02)=2.25KW. Use of DC Power DC socket only supplies for 12V automatic battery charging.
  • Page 18: Shut Off The Engine

     If you accidentally swallow the electrolyte, drink plenty of water or milk immediately, and then drink milk or vegetable oil with magnesium oxide and seek medical care.  Batteries and electrolytes should be placed where children are not accessible. DC protector When using AC power, you can use DC output at the same time .
  • Page 19: Maintenance

     Turn the engine switch to the ‘OFF’ position  Turn the fuel switch to “OFF” position. When not using the generator for a long time, please turn off the generator. 9. MAINTENANCE Maintenance and adjustment schedules are developed to keep the generator in the best working condition.
  • Page 20 Note:  Normal maintenance interval;  In areas where pollution is severe, check and repair frequently.  The above regular maintenance schedule is calculated at ambient temperature of 25°C. If the ambient temperature exceeds 30°C, reduce the load power of the generator or shorten the time interval for replacing the oil (choose one operation).
  • Page 21 BE CAUTIOUS  In order to comply with environmental requirements, we recommend that collect the waste oil into a sealed container, send to the local service station or recycling center near your location. Do not spill the oil on the ground or garbage. Maintenance of air filter The dirty air filter will block the air into the carburetor.
  • Page 22  If the insulator has been ruptured, it must be scrapped. If you want to use the spark plug again, use a brush to clean the spark plug.  Measure the spark plug clearance with a feeler gauge, and the spark plug clearance should be 0.6-0.7mm (0.024-0.028 in) ...
  • Page 23: Transportation/Warehousing

    10. TRANSPORTATION/WAREHOUSING To prevent fuel leakage during transport or temporary storage, turn off the oil switch and place the generator in a location where no fuel leaks. WARNING When transporting the generator:  Do not fill too much fuel into fuel tank. (There should be no fuel in the filler). ...
  • Page 24: Troubleshooting

     Exhaust oil.  Remove the spark plug, pour a tablespoon of clean oil into the cylinder, pull the start handle a few times to scatter the oil, and then install the spark plug back.  Pull the handle slowly until it feels pressure. At this moment, the piston is rising to the top of its compression stroke and the exhaust valve is closed.
  • Page 25 the engine, and the other end connect to the side electrode of the spark plug.)  Pull the start handle, spark should jump from the gap. NOTICE  Ensure that the engine is cooled down when you check the spark plug, or the high temperature of the engine and spark plug will cause burns.
  • Page 26: Specifications

    12. SPECIFICATIONS Engine Model No. XG-170F Engine type 4-stroke, single cylinder, OHV Displacement( CC) 207cc Rated speed 3600/min Compression ratio Starting system Recoil Fuel Volume (L) Lube. Oil capacity (L) 0.45 L Spark plug F7RTC Sound pressure level: L 74.79 dB(A), K = 0.79dB(A) Sound power level L 94.79 dB(A), K = 0.79dB(A) Guaranteed sound power level...
  • Page 27: Circuit Diagram

    13. CIRCUIT DIAGRAM...
  • Page 28: Declaration Of Conformity

    States that the designated below machine: Product: Petrol Inverter generator LOW POWER GENERATING SET Model: FGHI3500RS Serial number: 20230403705-20230403928 is in confirmity with the essential requirements and other relavant provisions of the applicable European Directives,based on the application of European harmonized standerds.Any unauthorized modification of the apparatus voids this declaration.
  • Page 29: Warranty

    1 5 . WARRANTY WARRANTY The manufacturer guarantees the product against defects in material and workmanship for a period of 2 years from the date of the original purchase. The warranty only applies if the product is for household use. The warranty does not cover breakdowns due to normal wear and tear.
  • Page 30: Product Failure

    1 6 . PRODUCT FAILURE WHAT TO DO IF MY MACHINE BREAKS DOWN? If you bought your product in a store: a) Empty the fuel tank if your product has one. b) Make sure that your machine is complete with all accessories supplied, and clean! If this is not the case, the repairer will refuse the machine.
  • Page 31: Warranty Exclusions

    17. WARRANTY EXCLUSIONS THE WARRANTY DOES NOT COVER: • Start-up and setting up of the product. • Damage resulting from normal wear and tear of the product. • Damage resulting from improper use of the product. • Damage resulting from assembly or start-up not in accordance with the user manual. •...