  • Page 1 ORIGINA LINSTRUCTIONS >EN GASOLINE INVERTER GENERATOR LOW VOLTAGE GENERATING SET FG2000i-B USER GUIDE WARNING: Read the instructions carefully before using this machine!
  • Page 2: Table Of Contents

    CONTENTS 1. SAFETY INSTRUCTIONS ....................... 3 2. SAFETY WARNING LABEL ....................6 3. COMPONENTS IDENTIFICATION ..................7 4. CONTROL SYSTEM ....................... 9 5. PREPARATION ........................10 6. GENERATOR USE ....................... 13 7. STARTING THE ENGINE ...................... 15 8. MAINTENANCE ........................18 9.
  • Page 3: Safety Instructions

    1. SAFETY INSTRUCTIONS WARNING: 1) Attention! Exhaust gases are toxic. Do not operate the generator in a room without ventilation system! 2) Children should be protected by keeping them at a safe distance from the generator set! 3) Refilling of the generating sets are not allowed during the operation! 4) If the generator will be mounted in a closed room, relevant safety regulations against fire and explosion should be followed! 5) Do not connect to household circuit!
  • Page 4 ● Clean the components of the air filter periodically, and replace the air filter when necessary. ● Remove any electrical equipment that is plugged in before starting or stopping the generator. ● Before transporting the generator, you must empty the fuel tank. ●...
  • Page 5 building must be performed by a qualified electrician, and in conformity to the provisions of the applicable laws and norms in the field of electricity. Incorrect connections will cause leakage of the current from the generator into the lines of the public electricity company. Such leakage could electrocute the workers of the public electricity company working on the network or other persons in contact with the line during a power cut.
  • Page 6: Safety Warning Label

    2. SAFETY WARNING LABEL Safety warning label: Guaranteed sound power level...
  • Page 7: Components Identification

    3. COMPONENTS IDENTIFICATION 3.1 Components Feature...
  • Page 8 3.2 Control Panel Factory will adjust the panel according to different configuration. Please note that subject to change without prior notice. AC reset ECO switch Low oil indicator (Yellow) AC socket 230V Overload Indicating Light (Red) Ground terminal Running indicator (Green) AC socket 230V...
  • Page 9: Control System

    4. CONTROL SYSTEM 4.1 Engine oil alerting system(YELLOW) The engine oil protection system will stop the engine automatically, and the engine oil indicating lights, while the oil in crankcase is under safe line;Fill the engine oil to the oil level, it can be restart again.
  • Page 10: Preparation

    5. PREPARATION 5.1 Fuel Oil ● Please use unleaded gasoline, E10 or higher level. ● Do not use a mixture of oil and gasoline or dirty gasoline. ● Prevent dirt and water from entering the tank. ● Do not use gasoline containing more than 10% ethanol or gasoline containing methanol, otherwise the engine will be seriously damaged.
  • Page 11 ● Do not use 2-stroke oil or detergents-free oil, otherwise the engine life will be shortened. ● Use high-quality 4-stroke oil that meets or exceeds the SG,SF classification of the American Petroleum Association required by American automakers. ● Select oil suitable viscosity according to the average temperature in your area. ●...
  • Page 12 ● Snap open the Air Cleaner cover, and remove it. ● Take out the air filter element. If necessary, clean or replace the filter element. ● The engine is not allowed to run without an air filter element, otherwise the dirt will enter the engine through the carburetor and cause rapid wear and tear.
  • Page 13: Generator Use

    6. GENERATOR USE ● Applicable temperature:-5℃~40℃ ● Applicable humidity: below 95% ● Applicable altitude:areas below 1000 meters(If you operate your engine at altitudes above 1000 meters, reduce the engine power or modify the carburetor by contacting the suppliers. 6.1 Connect to Household Power Supply When the generator is connected to the household power supply as a standby power supply, it should be connected by a special electrician or someone familiar with the electricity.
  • Page 14 shall not exceed the rated power of the generator. Overload operation will lead to generator stalling or greatly shorten the life of the generator. If there are multiple loads or electrical equipment connected to the generator set, please keep in mind that: first turn on the highest starting load, then turn on the second, and finally turn on the lowest starting load.
  • Page 15: Starting The Engine

    7. STARTING THE ENGINE 7.1 Recoil Start ● Disconnect the electrical equipment from the alternator's AC socket before starting the engine. ● For initial use (long unused, start after gasoline is used up), turn the engine switch knob to "ON" position for 10 to 20 seconds before starting, so that gasoline can enter the engine carburetor.
  • Page 16 3) Gently pull the start handle until the resistance is felt, and then pull it in the direction indicated by the arrow in the following figure. ● Pay attention to pull the starting handle, the pull angle should not be too large, so as not to wear the housing shell.
  • Page 17 7.2 Stopping the Engine 1) Turn the ECO switch to “OFF”; 2) Disconnect any electric devices. 3) Turn the engine switch to “OFF”; 4) The tank cap switch rotates to "OFF" position ● To stop the engine in an emergency, turn the Engine Switch to the “OFF" position. ●...
  • Page 18: Maintenance

    8. MAINTENANCE AND STORE Safety is an obligation of the owner. Periodic inspection, adjustment and lubrication will keep your generator in the safest and most efficient condition possible. In order to keep the engine in good condition, you must check and maintain it regularly. Please follow the schedule below. Maintenance Schedule Regular Service Period(3)...
  • Page 19 4).Refill the recommended oil and check the oil level. 5).Re-install the air filter maintenance cover and tighten the dipstick.
  • Page 20 For conforming to the environment requirement, the used oil will be put into a sealed container and then be transported to the service station for recycle. Do not throw it into the trash or pour it on the ground. 8.2 Air Filter Maintenance Dirty air filters will affect the flow of air into carburetors.
  • Page 21: Transporting / Storing

    5) Check that if the spark plug gasket is in good condition. Install the spark plug, tighten it with the spark plug socket wrench, and press down the spark plug gasket. Cover the spark plug cap. Please use spark plugs with appropriate calorific value. 9.
  • Page 22 2) Turn the engine switch to “ON” position, and loosen the carburetor drain screw to discharge gasoline inside of the suitable containers. 3) Take off the Spark Plug cap, pull the Starter handle three or four times, discharge the gasoline from the fuel pipe and carburetor.
  • Page 23: Troubleshooting

    10. TROUBLESHOOTING...
  • Page 24: Electrical Diagrams

    11. ELECTRICAL DIAGRAMS...
  • Page 25: Technical Specifications

    12. TECHNICAL SPECIFICATIONS Model FG2000i-B Engine Type Single Cylinder, 4 Stroke, Air Cooling Displacement 80 cm Ignition System Spark ignition Starting Type Recoil Start Oil Capacity 0.35 L Measured sound power level, LwA 87.44dB(A), K =1,13dB(A) Guaranteed sound power level...
  • Page 26: Declaration Of Conformity

    BUILDER SAS ZI, 32 RUE ARISTIDE BERGES – 312070 CUGNAUX – FRANCE Declares that the machinery designated below: GASOLINE INVERTER GENERATOR: FG2000i-B Serial number: 20230218390-20230218715 Complies with the provisions of the Directive “machinery” 2006/42/CE and national laws transposing it: Also complies with the following European directives: EMC Directive 2014/30/EU;...
  • Page 27: Warranty

    BUILDER SAS 32, rue Aristide Bergè s - ZI 31270 Cugnaux - France MADE IN PRC 2023...