    CONTENTS SAFETY INSTRUCTION ..................3 COMPONENT IDENTIFICATION..............7 INSTALLATION....................9 CONTROLS.....................12 GENERATOR USE..................14 PRE-OPERATION CHECK................17 STARTING / STOPPING THE ENGINE............19 MAINTENANCE....................19 TRANSPORTING AND STORAGE..............22 TROUBLESHOOTING..................24 WIRING DIAGRAM..................26 SPECIFICATIONS...................28 EC DECLARATION OF CONFORMITY............29 WARRANTY....................30 PRODUCT FAILURE..................31 WARRANTY EXCLUSIONS................32...
  • Page 3: Safety Instruction

    1.SAFETY INSTRUCTION WARNING: • Attention! Exhaust gases are toxic. Do not operate the generator in a room without ventilation system! • Children should be protected by keeping them at a safe distance from the generator set! • Refilling of the generating sets are not allowed during the operation! •...
  • Page 4  Periodically check the installation of the connections and the tightness of the fixations, re- tightening them if necessary.  Clean the components of the air filter periodically, and replace the air filter when necessary.  Remove any electrical equipment that is plugged in before starting or stopping the generator. ...
  • Page 5  If you swallow fuel by mistake, if you inhale fuel vapours or if you get drops of fuel in your eyes, see a doctor immediately. If a certain quantity of fuel is spilt on your skin or clothing, wash or change your clothes.
  • Page 6  To dispose residual fluids, proceed as follows: - Close the fuel tap - Drain fuel from the fuel tank - Empty carburetor fuel SYMBOL EXPLANATION Attention! Please read the manual carefully before using the unit! Conforms to relevant safety standards Do not dispose of old appliances with domestic rubbish .
  • Page 7: Component Identification

    It is forbidden to run the generator in an enclosed room because exhaust emissions can lead humans or animals to coma to death. Do not connect with the electricity system. Hot surfce, do not touch. Warning, no oil in engine. Add engine oil before using.
  • Page 8 FG8500RS panel and rating label: FG8500ES panel and rating label:...
  • Page 9: Installation

    3. INSTALLATION 3.1 UNPACKING 1) Unpack all parts and lay them on a flat stable surface 2) Make sure the delivery contents are complete and free of damage. If you find that parts are missing or show damage, do not use the product but contact your dealer/service centre. Do not use the product unless missing parts have been delivered in addition or defective parts have been replaced.
  • Page 10 3.3 WHEELS Put upside down the generator. Assemble the axis and wheel on one side of the support. Assemble the axis and wheel on other side of the support. 3.4 FOOT PAD Keep the tool upside down. Localise the two holes on the bracket. Screw it in each hole.
  • Page 11 3.5 HANDLE Press the button then rolling over the handle. Screw the support with screws and nuts.
  • Page 12: Controls

    START: To start the engine by turning the starter motor. For FG8500ES For FG8500RS Turn the key to the ON position once the engine has started. Do not use the starter for more than 5 seconds at a time. If the engine does not start, release the switch and wait 10 seconds before trying to start again.
  • Page 13 4.4 CHOKE LEVER The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed by operating the choke lever or choke rod manually. Move the lever or the rod to the CLOSE position to enrich the mixture.
  • Page 14: Generator Use

    5. GENERATOR USE 5.1 CONNECTIONS TO A BUILDING’S ELECTRICAL SYSTEM Connections for standby power to a building's electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.
  • Page 15 Exceeding the time limit for maximum power operation or slightly overloading the generator may not switch the circuit breaker OFF, but will shorten the service life of the generator. Limit operation requiring maximum power to 30 minutes. For continuous operation, do not exceed the rated power. In any case, the total power requirements (VA) of all appliances connected must be considered.
  • Page 16 WARNING The battery gives off explosive gases; keep spark, flames and cigarettes away. Provide adequate ventiiatlon when charging or using batteries. 2) Connect the positive (+) battery cable to the battery positive (+) terminal. 3) Connect the other end of the positive (+) battery cable to the generator. 4) Connect the negative (-) battery cable to the battery negative (-) terminal.
  • Page 17: Pre-Operation Check

    6. PRE-OPERATION CHECK 6.1 ENGINE OIL NOTICE: Engine oil is a major factor affecting engine performance and service life. Non- detergent and 2-stroke engine oils will damage the engine and are not recommended. Check the oil level BEFORE EACH USE with the generator on a level surface with the engine stopped.
  • Page 18 Use gasoline with a pump octane rating of 86 or higher. We recommend unleaded gasoline because it produces fewer engine and spark plug deposits and extends exhaust system life. Never use stale or contaminated gasoline or oil/gasoline mixture. Avoid getting dirt or water in the fuel tank.
  • Page 19: Starting/Stopping The Engine

    Turn the choke lever or to the CLOSE position, or pull the choke rod out to the CLOSE position. • Start the engine • With recoil starter (for FG8500RS) Turn the engine switch to the ON position. Pull the starter grip until compression is felt, then pull briskly. NOTICE Do not allow the starter grip to snap back against the engine.
  • Page 20 Change Air cleaner Check Clean o(1) Sediment Cup Clean Spark plug Check-Clean Spark arrester Clean Valve clearance Check-Adjust o(2) Fuel tank and Clean o(2) strainer Fuel line Check Every 2 years (Replace if necessary) (2) 1) Service more frequently when used in dusty areas. 2) These items should be serviced by an authorized generator dealer, unless the owner has the proper tools and is mechanically proficient.
  • Page 21 Do not throw it in the trash or pour it on the ground. 8.4 AIR CLEANER SERVICE A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas. WARNING Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion.
  • Page 22: Transporting And Storage

    The gap should be: 0.70-0.80 mm (0.028-0.031 in). 6) Check that the spark plug washer is in good condition, and thread the spark plug in by hand to prevent cross-threading. 7) After the spark plug is seated, tighten with a spark plug wrench to compress the washer.
  • Page 23 WARNING Gasoline is extremely flammable and is explosive under certain conditions. Perform this task in a well ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area during this procedure. The fuel of this machine is combustible and deflagrating. After the machine has been shut down, the additional fuel must be treated properly and the local environmental requirements must be met.
  • Page 24: Troubleshooting

    10. TROUBLESHOOTING When the engine will not start: Is there fuel in the tank? Refill the fuel tank Is there oil in the tank? Add the recommended oil. STILL SPARK Is there spark from Replace the Take the generator to an spark plug.
  • Page 25 No electricity at the AC receptacles Is the AC circuit breaker ON Turn the AC circuit breaker ON NO DEFECTS Check the electrical appliance or Take the generator to an equipment for any defects. authorized generator dealer. Replace the electrical appliance DEFECTS or equipment.
  • Page 26: Wiring Diagram

    11. CIRCUIT DIAGRAM...
  • Page 28: Specifications

    12. SPECIFICATIONS Reference: FG8500RS FG8500ES Engine model HP192F/P Engine type Single cylinder, 4-strokes, Forced air cooling, OHV. Displacement( CC) 460cm Rated speed 3000/min Igniting system Electronic ignition Starting system Recoil Recoil / Electric starter Engine Fuel Volume (L) 30 L...
  • Page 29: Ec Declaration Of Conformity

    ZI, 32 RUE ARISTIDE BERGES – 312070 CUGNAUX – FRANCE Declares that the machinery designated below: Gasoline Generator Model: FG8500RS/FG8500ES Serial number: 20221111977- 20221112106 / 20221112114-20221112251 Complies with the provisions of the Directive “machinery” 2006/42/CE and national laws transposing Also complies with the following European directives: EMC Directive 2014/30/EU Emission directive (EU) 2016/1628 &...
  • Page 30: Warranty

    14. WARRANTY The manufacturer guarantees the product against defects in material and workmanship for a period of 2 years from the date of the original purchase. The warranty only applies if the product is for household use. The warranty does not cover breakdowns due to normal wear and tear. The manufacturer agrees to replace parts identified as defective by the designated distributor.
  • Page 31: Product Failure

    15. PRODUCT FAILURE WHAT TO DO IF MY MACHINE BREAKS DOWN? If you bought your product in a store: • Empty the fuel tank. • Make sure that your machine is complete with all accessories supplied, and clean! If this is not the case, the repairer will refuse the machine.
  • Page 32: Warranty Exclusions

    16. WARRANTY EXCLUSIONS THE WARRANTY DOES NOT COVER: • Start-up and setting up of the product. • Damage resulting from normal wear and tear of the product. • Damage resulting from improper use of the product. • Damage resulting from assembly or start-up not in accordance with the user manual. •...
  • Page 33 BUILDER SAS 32, rue Aristide Bergès - ZI 31270 Cugnaux – France Made in PRC 2022...

This manual is also suitable for:

Fg8500es

Table of Contents