Feider Machines FG7000RE Instruction Manual

Feider Machines FG7000RE Instruction Manual

Gasoline generator

Advertisement

Quick Links

ORIGINAL INSTRUCTIONS > EN
Gasoline Generator
Instruction Manual
Model: FG7000RE
Feider France
32, rue Aristide Bergès - ZI 31270 Cugnaux - France
Made in PRC
Warning: Please read the manual carefully before using the unit!
1

Advertisement

Table of Contents
loading

Summary of Contents for Feider Machines FG7000RE

  • Page 1 ORIGINAL INSTRUCTIONS > EN Gasoline Generator Instruction Manual Model: FG7000RE Feider France 32, rue Aristide Bergès - ZI 31270 Cugnaux - France Made in PRC Warning: Please read the manual carefully before using the unit!
  • Page 2: Table Of Contents

    CONTENTS 1. SAFETY INSTRUCTION 2. COMPONENT IDENTIFICATION 3. CONTROLS 1) Engine Switch 2) Recoil Starter 3) Fuel Valve 4) Choke 5) Circuit Breaker 6) Ground Terminal 7) Oil Alert System 4. GENERATOR USE 1) Connections to a Building's Electrical System 2) Ground System 3) AC Applications 4) AC Operation...
  • Page 3: Safety Instruction

    1. SAFETY INSTRUCTION Warning: 1. Attention! Exhaust gases are toxic. Do not operate the generator in a room without ventilation system! 2. Children should be protected by keeping them at a safe distance from the generator set! 3. Refilling of the generating sets are not allowed during the operation! 4.
  • Page 4 Run the generator in respect of the power indicated in the user’s manual. Do not run the generator with an  overload or at excessive speed. The silencer of the generator becomes extremely hot when the motor runs or even for a time after it has ...
  • Page 5 Engine exhaust gases are toxic. Do not operate the generating set in unventilated rooms. When installed in  ventilated rooms, additional requirements for fire and explosion protection shall be observed.  Before use, the generating set and its electrical equipment (including lines and plug connections) should be checked to ensure that they are not defective.
  • Page 6 Make sure that the fuel cap is tightly closed before starting.   Do not keep petrol in the tank for a long time. While using or transporting the generator, make sure you keep the generator upright, otherwise the  fuel may escape from the carburettor or the fuel tank.
  • Page 7 Before connecting electrical devices to the generator, make sure that their voltage specifications and frequency of functioning correspond to the technical characteristics of the generator. There may be damage if the device connected is not designed to function with a voltage tolerance of +/- 10% or a frequency tolerance of +/- 3 % compared with those of the generator.
  • Page 8 No naked flames Ground connection It is forbidden to run the generator in an enclosed room because exhaust emissions can lead humans or animals to coma to death. This symbol indicates the surface is very hot and not touching Keep away from the machine Exhaust emissions are harmful to health of body Do not connect with the electricity system.
  • Page 9: Component Identification

    2. COMPONENT IDENTIFICATION Fuel tank Circuit breaker Fuel valve Choke socket level Handle cleaner Ground terminal Recoil starter grip Voltmeter Engine switch Betttery Oil filter terminals Wheels 3. CONTROLS 1) Engine Switch To start and stop the engine. Switch position: OFF: To Stop the engine.
  • Page 10 Return the key to the ON position once the engine has started. Do not use the starter for more than 5 seconds at a time. If the engine fails to start, release the switch and wait 10 seconds before operating the starter again. 2) Recoil Starter To start the engine, pull the starter grip lightly until resistance is felt, then pull briskly.
  • Page 11: Generator Use

    5) Circuit Breaker The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of the generator at the receptacle. If the circuit breaker is switched OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before switching the circuit breaker ON again.
  • Page 12 CAUTION Improper connections to a building’s electrical system can allow electrical current from the utility company to feedback into the generator. When utility power is restored, the generator may explode, burn, or cause fires in the building’s electrical system. 2) Ground System To prevent electrical shock from faulty appliances, the generator should be grounded.
  • Page 13 Substantial overloading will switch off the circuit breaker. Exceeding the time limit for maximum power operation or slightly overloading the generator may not switch the circuit breaker OFF, but will shorten the service life of the generator. Limit operation requiring maximum power to 30 minutes. For continuous operation, do not exceed the rated power.
  • Page 14 The indicator inside the DC circuit protector button will pop out to show that the DC circuit protector has switched off. Wait a few minutes and push the button in to reset the DC circuit protector. Connecting the battery cables: 1) Before connecting charging cables to a battery that is installed in a vehicle, disconnect the vehicle’s grounded battery cable.
  • Page 15: Pre-Operation Check

    Disconnecting the battery cables: 1) Stop the engine. 2) Disconnect the negative (-) battery cable from the generator negative (-) terminal. 3) Disconnect the other end of the negative (-) battery cable from the battery negative (-) terminal. 4) Disconnect the positive (+) battery cable from the generator positive (+) terminal. 5) Disconnect the other end of the positive (+) battery cable to the battery positive (+) terminal.
  • Page 16 Use 4-stroke oil, or equivalent high detergent, premium quality motor oil certified to meet or exceed U.S. automobile manufacturer’s requirements for Service Classification SG, SF/CC, CD. Motor oils classified SG, SF/CC, CD will show this designation on the container. SAE 10W-30 is recommended for general temperature use. Other viscosities shown in the chart may be used when the average temperature in your area is within the indicated range.
  • Page 17 • Do not overfill the fuel tank (there should be no fuel in the filler neck). After refueling, make sure the tank cap is closed properly and securely. Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may ignite. If any fuel is spilled, make sure the area is dry before starting the engine. •...
  • Page 18: Starting/Stopping The Engine

    Ethanol (ethyl or grain alcohol) Gasoline containing more than 10% ethanol by volume may cause starting or performance problems. Gasoline containing ethanol may be marketed under the name “Gasohol". Methanol (methyl or wood alcohol) Gasoline containing methanol must contain cosolvents and corrosion inhibitors to protect the fuel system.
  • Page 19: Maintenance

    NOTICE Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter or housing. • With electric starter: (Optional kit) Turn the engine switch to the START position and hold it there for 5 seconds or until the engine starts.
  • Page 20 1) MAINTENANCE SCHEDULE REGULAR SERVICE PERIOD Each First Every 3 Every 6 Every Performed at every indicated month or month or months or months or year or operating hour interval, whichever 20 Hrs. 50 Hrs. 100 Hrs. 300 Hrs. comes first. ITEM Engine oil Check level...
  • Page 21 NOTE: Diagrams may vary according to the types. 3) Engine oil change Drain the oil while the engine is warm to assure complete and rapid draining 1. Remove the drain plug and sealing washer, oil filler cap, and drain the oil 2.
  • Page 22 WARNING Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion. Use only soapy water or nonflammable solvent. NOTICE Never run the generator without the air cleaner. Rapid engine wear will result. 1) Unsnap the air cleaner cover clips, remove the air cleaner cover, and remove the element. 2) Wash the element in a solution of household detergent and warm water, then rinse thoroughly;...
  • Page 23 5) Fuel Sediment Cup Cleaning The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. 1) Turn the fuel valve to the OFF position.
  • Page 24: Transporting And Storage

    The gap should be: 0.70-0.80 mm (0.028-0.031 in). 6) Check that the spark plug washer is in good condition, and thread the spark plug in by hand to prevent cross-threading. 7) After the spark plug is seated, tighten with a spark plug wrench to compress the washer. If installing a new spark plug, tighten I/2 turn after the spark plug seats to compress the washer.
  • Page 25 STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required. 1 to 2 months Fill with fresh gasoline and add gasoline conditioner* 2 months to 1 year Fill with fresh gasoline and add gasoline conditioner* Drain the carburetor float bowl.
  • Page 26 4) Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its compression stroke and both the intake and exhaust valves are closed Storing the engine in this position will help to protect it from internal corrosion. Align the notch on the starter pulley with the hole at the top of recoil starter.
  • Page 27: Troubleshooting

    9. TROUBLESHOOTING When the engine will not start: Is there fuel in the tank? Refill the fuel tank Is there oil in the tank? Add the recommended oil. STILL SPARK Is there spark from Replace the Take the generator to an spark plug.
  • Page 28 No electricity at the AC receptacles Is the AC circuit breaker ON Turn the AC circuit breaker ON Check the electrical appliance or Take the generator to an equipment for any defects. authorized generator dealer. Replace the electrical appliance DEFECTS or equipment.
  • Page 29 10. CIRCUIT DIAGRAM...
  • Page 30: Specifications

    11. SPECIFICATIONS Engine Engine model LT420 Engine type Single cylinder, 4-strokes, Forced air cooling, OHV. Displacement( CC) 420cc Rated speed 3000/min Igniting system Transistor magneto Starting system Recoil/Electric Fuel Volume (L) 25 L Continuous operation time (h) Min. Fuel consumption (g/kW.h) 313 g/kW.h Lube.
  • Page 31 Labels affixed on the machine...
  • Page 32: Ec Declaration

    FRANCE FRANCE ZI, 32 RUE ARISTIDE BERGES – 312070 CUGNAUX – FRANCE Declares that the machinery designated below: Gasoline Generator FG7000RE Model: Serial number: 20220651212-20220651356 Complies with the provisions of the Directive “machinery” 2006/42/CE and national laws transposing it: Also complies with the following European directives:...
  • Page 33: Warranty

    13. WARRANTY WARRANTY The manufacturer guarantees the product against defects in material and workmanship for a period of 2 years from the date of the original purchase. The warranty only applies if the product is for household use. The warranty does not cover breakdowns due to normal wear and tear. The manufacturer agrees to replace parts identified as defective by the designated distributor.
  • Page 34: Product Failure

    14. PRODUCT FAILURE WHAT TO DO IF MY MACHINE BREAKS DOWN? If you bought your product in a store: a) Empty the fuel tank. b) Make sure that your machine is complete with all accessories supplied, and clean! If this is not the case, the repairer will refuse the machine.
  • Page 35: Warranty Exclusions

    15. WARRANTY EXCLUSIONS THE WARRANTY DOES NOT COVER: • Start-up and setting up of the product. • Damage resulting from normal wear and tear of the product. • Damage resulting from improper use of the product. • Damage resulting from assembly or start-up not in accordance with the user manual. •...

Table of Contents