Download Print this page
Feider Machines FGHi3500 Original Instructions Manual

Feider Machines FGHi3500 Original Instructions Manual

Low power dual fuel generator

Advertisement

Quick Links

ORIGINAL INSTRUCTIONS > EN
LOW POWER DUAL FUEL GENERATOR
MODEL: FGHi3500
ORIGINAL INSTRUCTIONS
BUILDER SAS
ZI -32, rue Aristide Bergès, 31270 Cugnaux, France
Made in P.R.C. 2021
Warning: Please read the manual carefully before using the unit!
1

Advertisement

loading

Summary of Contents for Feider Machines FGHi3500

  • Page 1 ORIGINAL INSTRUCTIONS > EN LOW POWER DUAL FUEL GENERATOR MODEL: FGHi3500 ORIGINAL INSTRUCTIONS BUILDER SAS ZI -32, rue Aristide Bergès, 31270 Cugnaux, France Made in P.R.C. 2021 Warning: Please read the manual carefully before using the unit!
  • Page 2: Table Of Contents

    ORIGINAL INSTRUCTIONS > EN CONTENTS 1. SAFETY WARNINGS 2. COMPONENT IDENTIFICATION 3. ASSEMBLY 4. OPERATION 5. MAINTENANCE AND STORAGE 6. SPECIFICATIONS 7. TROUBLESHOOTING 8. DECLARATION OF CONFORMITY...
  • Page 3: Safety Warnings

    ORIGINAL INSTRUCTIONS > EN SAFETY WARNINGS  The operator must know the principles of functioning and the structure of the generator and the motor. He must know how to stop the motor in case of urgency and how to manipulate the controls. ...
  • Page 4 ORIGINAL INSTRUCTIONS > EN  Clean the components of the air filter periodically, and replace the air filter when necessary.  Remove any electrical equipment that is plugged in before starting or stopping the generator.  Before transporting the generator, you must empty the fuel tank. ...
  • Page 5 ORIGINAL INSTRUCTIONS > EN  Fuel is combustible and easily ignited. Do not refuel during operation. Do not refuel while smoking or near naked flames. Do not spill fuel.  Some parts of the internal combustion engine are hot and may cause burns. Pay attention to the warnings on the generating set.
  • Page 6 ORIGINAL INSTRUCTIONS > EN  Never fill the fuel tank while smoking or near a naked flame.  Make sure you don’t spill fuel on the motor and the exhaust grille of the generator during filling with fuel.  Keep the fuel in an appropriate recipient and sheltered from any sources of fire. ...
  • Page 7 ORIGINAL INSTRUCTIONS > EN Before connecting electrical devices to the generator, make sure that their voltage specifications and frequency of functioning correspond to the technical characteristics of the generator. There may be damage if the device connected is not designed to function with a voltage tolerance of +/- 10% or a frequency tolerance of +/- 3 % compared with those of the generator.
  • Page 8 ORIGINAL INSTRUCTIONS > EN Symbol explanation Attention! Please read the manual carefully before using the unit! Conforms to relevant safety standards Do not dispose of old appliances with domestic rubbish. Guaranteed sound power level No naked flames Ground connection It is forbidden to run the generator in an enclosed room because exhaust emissions can lead humans or animals to coma to death.
  • Page 9: Component Identification

    ORIGINAL INSTRUCTIONS > EN 2. COMPONENT IDENTIFICATION (1) Carrying Handle (5) Maintenance Cover-Oil filter, Air filter and (2) Fuel Level vent- Turn this valve to the “On” Carburetor access position to supply air to the tank (6) Muffler (3) Fuel Cap – Remove to add fuel. (4) Recoil Starter –...
  • Page 10: Assembly

    ORIGINAL INSTRUCTIONS > EN 3. ASSEMBLY Your generator requires some assembly. This unit is shipped from our factory without oil. It must be properly serviced with fuel and oil before operation. Remove the Generator from the Shipping Carton 1. Set the shipping carton on a solid, flat surface. 2.
  • Page 11 ORIGINAL INSTRUCTIONS > EN NOTE Weather will affect engine oil and engine performance. Change the type of engine oil used based on weather conditions to suit the engine needs. NOTE Synthetic oil may be used after the 5 hour initial break-in period. Using synthetic oil does not increase the recommended oil change interval.
  • Page 12 ORIGINAL INSTRUCTIONS > EN 1. Use clean, fresh, regular unleaded fuel with a minimum octane rating of 85 and an ethanol content of less than 10% by volume. 2. DO NOT mix oil with fuel. 3. Clean the area around the fuel cap. 4.
  • Page 13 ORIGINAL INSTRUCTIONS > EN NOTE — Use only standard 20 or 30 pound capacity LP tanks with Type 1, right hand Acme threads. — Verify the requalification date on the tank has not expired. — All new cylinders must be purged of air and moisture prior to filling. Used cylinders that have not been plugged or kept closed must also be purged.
  • Page 14: Operation

    ORIGINAL INSTRUCTIONS > EN 4. OPERATION Generator Location NEVER operate the generator inside any building, including garages, basements, crawl spaces and sheds, enclosure or compartment, including the generator compartment of a recreational vehicle. Please consult your local authority. In some areas, generators must be registered with the local utility. Generators used at construction sites may be subject to additional rules and regulations.
  • Page 15 ORIGINAL INSTRUCTIONS > EN NOTE When the fuel selector switch is in 3 o’clock position, the gas valve is OPEN, to close the gas fuel valve, turn the selector switch to 12 o’clock position Starting the Inverter CAUTION: If the ignition switch is held down in the Start” position longer than 5 seconds it could damage the NOTE: If the engine starts but does not continue to run make certain that the generator is on a flat, level surface.
  • Page 16 ORIGINAL INSTRUCTIONS > EN 10. If engine fails to start in 1-pull with choke in the “RUN” position, then pull choke out and repeat the PULL-TO-PRIME step. NOTE: Observing frost on LPG containers and regulators is common during operation and normally is not an indication of a problem.
  • Page 17 ORIGINAL INSTRUCTIONS > EN While charging a device do not place on the exhaust side of the generator. Extreme heat caused by exhaust can damage the device, and cause a potential fire hazard. Connecting Electrical Loads 1. Let the engine stabilize and warm up for a few minutes after starting 2.
  • Page 18: Maintenance And Storage

    ORIGINAL INSTRUCTIONS > EN engine is not in use. NOTE: When turning off the generator after LPG operation, make sure the LPG cylinder knob is in the fully closed position. NOTE: If the engine will not be used for a period of two (2) weeks or longer, please see the Storage section for proper engine and fuel storage MAINTENANCE AND STORAGE The owner/operator is responsible for all periodic maintenance.
  • Page 19 ORIGINAL INSTRUCTIONS > EN 6. Carefully thread the plug into the engine. 7. Use the spark plug tool to firmly install the plug. 8. Attach the spark plug wire to the plug. Air Filter 1. Remove the maintenance cover. 2. Locate the air filter plastic cover. 3.
  • Page 20 ORIGINAL INSTRUCTIONS > EN Adjustments The air-fuel mixture is not adjustable. Tampering with the governor can damage your generator and your electrical devices and will void your warranty. Maintenance Schedule Follow the service intervals indicated in the following maintenance schedule. Service your generator more frequently when operating in adverse conditions.
  • Page 21: Specifications

    ORIGINAL INSTRUCTIONS > EN Generator Storage 1. Add a properly formulated fuel stabilizer to the tank. 2. Be sure all appliances are disconnected from the generator. 3. Run the generator for a few minutes so the treated fuel cycles through the fuel system and carburetor. 4.
  • Page 22: Troubleshooting

    ORIGINAL INSTRUCTIONS > EN 12.2A (LPG) Performance class Quality class Max. temperature Max. altitude 1000m Protection class IP23M DC output 12V /8.3A Size (LxWxH) 590x450x480 Net weight 38kg Information Regulator Inlet connection : G2 (W21.7x1.814-G2- for regulator R5F )nut & hose of LPG Outlet: H1(M20x1.5) Capacity: 1,5 kg/h Outlet pressure: 37 Mbar...
  • Page 23: Declaration Of Conformity

    ZI, 32 RUE ARISTIDE BERGES – 312070 CUGNAUX – FRANCE Declares that the machinery designated below: LOW POWER DUAL FUEL INVERTER GENERATOR Model: FGHi3500 Serial number: 220201252740-20201252827 Complies with the provisions of the Directive “machinery” 2006/42/CE and national laws transposing it:...
  • Page 24 9. WARRANTY WARRANTY The manufacturer guarantees the product against defects in material and workmanship for a period of 2 years from the date of the original purchase. The warranty only applies if the product is for household use. The warranty does not cover breakdowns due to normal wear and tear. The manufacturer agrees to replace parts identifed as defective by the designated distributor.
  • Page 25 10. PRODUCT FAILURE WHAT TO DO IF MY MACHINE BREAKS DOWN? If you bought your product in a store: a) Empty the fuel tank. b) Make sure that your machine is complete with all accessories supplied, and clean! If this is not the case, the repairer will refuse the machine.
  • Page 26 11. WARRANTY EXCLUSIONS THE WARRANTY DOES NOT COVER: • Start-up and setting up of the product. • Damage resulting from normal wear and tear of the product. • Damage resulting from improper use of the product. • Damage resulting from assembly or start-up not in accordance with the user manual. •...