  • Page 1 ORIGINAL INSTRUCTIONS > EN Gasoline Generator Instruction Manual Model: FG4500-1 Feider France 32, rue Aristide Bergès - ZI 31270 Cugnaux - France Made in PRC Warning: Please read the manual carefully before using the unit!
  • Page 2: Table Of Contents

    CONTENTS 1. SAFETY INSTRUCTION 2. COMPONENT IDENTIFICATION 3. CONTROLS 1) Engine Switch 2) Recoil Starter 3) Fuel Valve 4) Choke 5) Circuit Breaker 6) Ground Terminal 7) Oil Alert System 4. GENERATOR USE 1) Connections to a Building's Electrical System 2) Ground System 3) AC Applications 4) AC Operation...
  • Page 3: Safety Instruction

    1. SAFETY INSTRUCTION Warning: 1. Attention! Exhaust gases are toxic. Do not operate the generator in a room without ventilation system! 2. Children should be protected by keeping them at a safe distance from the generator set! 3. Refilling of the generating sets are not allowed during the operation! 4.
  • Page 4 Run the generator in respect of the power indicated in the user’s manual. Do not run the generator with an  overload or at excessive speed. The silencer of the generator becomes extremely hot when the motor runs or even for a time after it has ...
  • Page 5 Engine exhaust gases are toxic. Do not operate the generating set in unventilated rooms. When installed in  ventilated rooms, additional requirements for fire and explosion protection shall be observed.  Before use, the generating set and its electrical equipment (including lines and plug connections) should be checked to ensure that they are not defective.
  • Page 6 Do not keep petrol in the tank for a long time.   While using or transporting the generator, make sure you keep the generator upright, otherwise the fuel may escape from the carburettor or the fuel tank. Electrical safety Before each use ensure that the load to be connected does not exceed the power of the current produced by the generator.
  • Page 7 Protection of the environment  You must periodically check the silencer (Before doing this, switch off the generator and let it cool completely). A damaged silencer increases noise.  Do not throw motor oil into the drains but deposit it at a collection point set up for that purpose. ...
  • Page 8: Component Identification

    It is forbidden to run the generator in an enclosed room because exhaust emissions can lead humans or animals to coma to death. This symbol indicates the surface is very hot and not touching Keep away from the machine Exhaust emissions are harmful to health of body No naked fire near the machine! Do not connect with the electricity system.
  • Page 9: Controls

    3. CONTROLS 1) Engine Switch To start and stop the engine. Switch position: OFF: To Stop the engine. Key can be removed/inserted. ON: To run the engine after starting. START: To start the engine by turning the starter motor. With Electric Starter Without Electric Starter Return the key to the ON position once the engine has started.
  • Page 10 4) Choke The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed by operating the choke lever or choke rod manually. Move the lever or the rod to the CLOSE position to enrich the mixture. 5) Circuit Breaker The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of the generator at the receptacle.
  • Page 11: Generator Use

    7) Oil Alert System The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the oil alert system will automatically shut down the engine (the engine switch will remain in the ON position).
  • Page 12 Special Requirements There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction. •...
  • Page 13 ②Switch the AC circuit breaker ON. ③ Plug in the appliance. Most motorized appliances require more than their rated wattage for startup. Do not exceed the current limit specified for any one receptacle. If an overloaded circuit causes the AC circuit breaker to switch OFF, reduce the electrical load on the circuit, wait a few minutes and then reset the circuit breaker.
  • Page 14 a) Use specifically designated battery. Use of any other battery may create a risk of injury and fire. b) Keep battery no damage, No make a connection from one terminal to another. Shorting the battery terminals together may cause burns or a fire. c) Under abusive conditions, liquid may be ejected from the battery;...
  • Page 15: Pre-Operation Check

    5000 feet (1500 meters) above sea level, have an authorized generator dealer perform this carburetor modification. Even with suitable carburetor jetting, engine horsepower will decrease approximately 3.5% for each 1000 foot (300 meter) increase in altitude. The effect of altitude on horsepower will be greater than this if no carburetor modification is made.
  • Page 16 2) Fuel Recommendation 1. Check the fuel level gauge. 2. Refill the tank if the fuel level is low. Do not fill above the shoulder of the fuel strainer. WARNING • Gasoline is extremely flammable and is explosive under certain conditions. •...
  • Page 17 If spark knock or pinging occurs at a steady engine speed, under normal load, change brands of gasoline. If spark knock or pinging persists, see an authorized generator dealer. NOTICE Running the engine with persistent spark knock or pinging can cause engine damage. Running the engine with persistent spark knock or pinging is misuse, and the Distributor's Limited Warranty does not cover parts damaged by misuse.
  • Page 18: Starting/Stopping The Engine

    6. STARTING/STOPPING THE ENGINE Starting the engine 1. Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to start if a load is connected. 2. Turn the fuel valve to the ON position. 3.
  • Page 19: Maintenance

    7. MAINTENANCE Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. WARNING Exhaust gas contains poisonous carbon modoxide. Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated. Periodic maintenance and adjustment is necessary to keep the generator in good operating condition.
  • Page 20 The maintenance schedule applies to normal operating conditions. If you operate your generator under severe conditions, such as sustained high-load or high-temperature operation, or use it in unusually wet or dusty conditions, consult your servicing dealer for recommendations applicable to your individual needs and use.
  • Page 21 Please dispose of used motor oil in a manner that is compatible with the environment We suggest you take it in a sealed container to your local service station or recycling center for reclamation. Do not throw it in the trash or pour it on the ground. 4) Air cleaner service A dirty air cleaner will restrict air flow to the carburetor.
  • Page 22 5) Fuel Sediment Cup Cleaning The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. 1) Turn the fuel valve to the OFF position.
  • Page 23: Transporting And Storage

    4) Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean the spark plug with a wire brush if it is to be reused. 5) Measure the plug gap with a feeler gauge. Correct as necessary by carefully bending the side electrode.
  • Page 24 WARNING Contact with a hot engine or exhaust system can cause serious bums or fires. Let the engine cool before transporting or storing the generator. Take care not to drop or strike the generator when transporting. Do not place heavy objects on the generator.
  • Page 25 The fuel of this machine is combustible and deflagrating. After the machine has been shut down, the additional fuel must be treated properly and the local environmental requirements must be met. 2) Change the engine oil 3) Remove the spark plug, and pour about a tablespoon of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, then reinstall the spark plug.
  • Page 26: Troubleshooting

    9. TROUBLESHOOTING When the engine will not start: Is there fuel in the tank? Refill the fuel tank Is there oil in the tank? Add the recommended oil. STILL SPARK Is there spark from Replace the Take the generator to an spark plug.
  • Page 27 No electricity at the AC receptacles Is the AC circuit breaker ON Turn the AC circuit breaker ON Check the electrical appliance or Take the generator to an equipment for any defects. authorized generator dealer. Replace the electrical appliance DEFECTS or equipment.
  • Page 28 10. CIRCUIT DIAGRAM...
  • Page 29: Specifications

    11. SPECIFICATIONS Engine Engine model LT420 Engine type Single cylinder, 4-strokes, Forced air cooling, OHV. Displacement( CC) 420cc Rated speed 3000/min Igniting system Transistor magneto Starting system Recoil /Electric Fuel Volume (L) 25 L Continuous operation time (h) Min. Fuel consumption (g/kW.h) 313 g/kW.h Lube.
  • Page 30: Ec Declaration

    ZI, 32 RUE ARISTIDE BERGES – 312070 CUGNAUX – FRANCE Declares that the machinery designated below: Gasoline Generator FG4500-1 Model: Serial number: 20210876326-20210876435 20210954383-20210954492 Complies with the provisions of the Directive “machinery” 2006/42/CE and national laws transposing it: Also complies with the following European directives: EMC Directive 2014/30/EU ROHS Directive (EU)2015/863 amending 2011/65/EU Emission directive (EU) 2016/1628 &...
  • Page 31: Warranty

    13. WARRANTY WARRANTY The manufacturer guarantees the product against defects in material and workmanship for a period of 2 years from the date of the original purchase. The warranty only applies if the product is for household use. The warranty does not cover breakdowns due to normal wear and tear. The manufacturer agrees to replace parts identified as defective by the designated distributor.
  • Page 32: Product Failure

    14. PRODUCT FAILURE WHAT TO DO IF MY MACHINE BREAKS DOWN? If you bought your product in a store: a) Empty the fuel tank. b) Make sure that your machine is complete with all accessories supplied, and clean! If this is not the case, the repairer will refuse the machine.
  • Page 33: Warranty Exclusions

    15. WARRANTY EXCLUSIONS THE WARRANTY DOES NOT COVER: • Start-up and setting up of the product. • Damage resulting from normal wear and tear of the product. • Damage resulting from improper use of the product. • Damage resulting from assembly or start-up not in accordance with the user manual. •...